![Hafele HH-WVG80C Instructions For Use Manual Download Page 10](http://html1.mh-extra.com/html/hafele/hh-wvg80c/hh-wvg80c_instructions-for-use-manual_3224775010.webp)
English
!
in compliance with the instructions provided.
!
Wear gloves when carrying out installation and
maintenance operations.
AIR VENT
(for ducting versions)
!
Prepare the hole and the air vent duct (150 mm
diameter).
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct with an as smooth as possible inside.
!
!
Do not connect the hood to smoke exhaust ducts
stoves, etc).
!
For the air vents comply with the provisions laid down
by the competent authorities.
In addition, the air must not be evacuated through a
purpose.
!
Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
sucked in by the heat source.
FILTERING OR DUCTING VERSION ?
Decide from the outset which type is to be installed.
in the ducting version (if possible).
Ducting version
through an exhaust duct (diameter 150 mm).
Filtering version
back into the room.
CONTROLS
Speed display
PU5:
ON/OFF Motor 4
th
speed
PU4:
ON/OFF Motor 3
rd
speed
PU3:
ON/OFF Motor 2
nd
speed
PU2:
ON/OFF Motor 1
st
speed
PU1:
ON/OFF Lights
5’ timer function:
Pressing
PU2
,
PU3
,
PU4, PU5
for two seconds
when the motor is set to the corresponding speed,
the
5’ timer
function is activated.
The corresponding LED starts blinking to display this
function.
If you change the speed while the timer is running, the
function is
NOT
deactivated. To deactivate the function,
press the blinking key for two seconds.
Buzzer:
Each time the key is pressed, a beep is sounded.
Filter alarm:
alarm is activated (all the LEDs come on). The alarm is
activated when the motor is off and remains displayed
for 30”. To deactivate the alarm, press one of the keys
for 2” during alarm display. After 120 hours of motor
LEDs blink). The alarm is activated when the motor is
off and remains displayed for 30”. To deactivate the
alarm, press one of the keys for 2” during alarm display.
- If the hood is left on (lights and/or motor), after 10
hours in the absence of commands from the user, it will
automatically switch to OFF condition with all services
switched off.
- The Buzzer emits a "beep" each time that a command
is set from the keyboard or remote control (optional)
- In the event of interruption of power during the hood, if
you restore the hood in the OFF state, then the engine
must be reactivate manually.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The 4th speed (intensive) is automatically lowered to 3rd
speed after 5 minutes of operation to optimise energy
consumption.