9. Extensions and connections
The system can be extended. The following connections are available on the
FT 200 / FT 200 CAP furniture terminal:
Fig. 2: FT 200 / FT 200 CAP connections
9.1 Connections to the potential free input/output
Fig. 3: Connections to the potential free input/output
Connection
Description
1
Reset button
• Reset
2
Potential-free input/output
• Relay output port NO, NC, COM
• Digital input port
• Connection via separate terminal clamp (green)
• Macros required
•
10. Installation examples, page 71
3
Power supply output
•
4
Power supply input
•
5
Furniture lock EFL 3 / EFL 3C
• Basic components
5
MLA 6P multi-lock adapter
• Extension
6
Signal generator, visual (LED)
• Extension
7
Acoustic signal generator (105 dB) • Extension
8
Antenna FAN 200
• Basic components
9
Multi-lock adapter MLA 8
• Extension
Connection
Description
1
Input
• e.g. switches
2
NO, NC, COM
• Relay (e.g. for alarm system; macro required)
COM
NC
NO
ins-src-732.22.024.book Seite 70 Mittwoch, 13. Oktober 2021 1:58 13