14
OPERATION MANUAL
Once assembly is complete, test run the machine to ensure it is properly connected to the
power and safety components are functioning correctly. Check that the direction of the motor
is correct, and make sure that the belt travels in the correct direction.
If the direction is incorrect, isolate the machine and have the electrician make changes to the
wiring.
If you find an unusual problem during the test run, immediately stop the machine, disconnect
it from power, and fix the problem BEFORE operating the machine again. The Troubleshooting
table in the Maintenance section of this manual may be able to help. If the problem persists
then contact your dealers service technician.
To test run the machine:
1. Connect the machine to the power supply.
2. Make sure that the manual has been read and that the safety instructions at the beginning
of the manual are understood. Make sure the machine has been setup correctly
3. Make sure all tools and objects used during set up have been cleared away from the
machine.
4. Turn the machine ON.
5 Make sure that the belt is traveling in the correct direction.
6. Listen to and watch for abnormal noises or actions. The machine should run smoothly
with little or no vibration or rubbing noises.
7. Any strange or unusual noises should be investigated and corrected before operating the
machine again. Always disconnect the machine from power supply when investigating or
correcting potential problems. Check the troubleshooting table on Page 18 in the
maintenance section for possible solutions to the problem. If no solution can be found then
contact your local dealer’s service engineer.
4.8 TEST RUN
Testing The Emergency Stop Button
Make sure that the emergency button has been reset.
Start the machine and then press the emergency stop
button. The machine should stop and the power should
be cut off. If the machine cannot be started then the
emergency stop is working correctly. To reset the
emergency stop twist the red top until it pops up.