4 (16)
5 (16)
Before starting installation the bathroom wall and floor should be protected
with a wet room membrane that also extends behind the installation wall.
all water pipes that are installed in the installation wall should be free from joints
and comply with the manufacturer’s instructions..
Provisions should be made to allow inspection and repair of couplings and the like.
If a seal is desired between the installation wall and the floor to facilitate cleaning,
a drainage slot must always be provided at the lowest point so that any leakage can
run out on to the floor and be discovered before damage occurs to the underlying
structure. Make sure the floor gradient is correct.
If the installation wall houses a built-in cistern with access from above,
we recommend that a removable cover panel is fitted to provide protection
above the installation wall, as this will facilitate inspection and servicing of the flush mechanism.
Ensure good ventilation inside the installation wall.
Turn off the water!
The pipes should be flushed through before the toilet is fitted. Hafa bears no responsibility for any malfunction
caused by foreign particles in the toilet.
A professional tradesman should fit the toilet and
connect it to the property’s pipe system.
Once the toilet is installed, check to ensure that all connections are secure, tighten if necessary. Max continuous
pressure 10 bar. Recommended work pressure: 0,5–10 bar.
The product is certified in accordance with standard EN14055.
NOTE!
Hafa disclaims all liability for damage to the product or other property if the assembly instructions
and installation rules are not followed. in these cases Hafas warranty is not applicable.
ENG
Tätskikt ska finnas på vägg och golv bakom, på sidorna och över fixtur och cistern. (Den streckade
linjen). Spolcistern som byggs in i vägg skall placeras i utrymme med dränering av tillräcklig kapaci-
tet. Dränering skall mynna på en plats där man omedelbart kan upptäcka eventuellt läckage och
där utläckande vatten inte direkt orsakar skada. Golvet i det utrymme där spolcisternen monteras
bör luta mot dräneringen.
You should use sealing material on the floor and behind, beside and over the consealed system.
(The dotted line). A consealed system built into a wall shall be placed in a space where there is
enough capacity for drainage. The drainage shall exit in a place where you immideately can disco
-
ver any leakage. In is recommended that the floor declines towards the drainage.
Denna produkt är anpassad till
Branschregler Säker Vatteninstallation.
Hafa garanterar produktens
funktion om branschreglerna och
monteringsanvisningarna följs.
Ett auktoriserat VVS-företag är garanti för
att installationen utförs fackmannamässigt.