background image

Connectivity

7

Haemonetics

®

 

Cell Saver

® 

Elite

®

/Elite

®

+ User Manual

P/N 120857-US, Manual Revision: AC

the settings, either silently

 

or with a notification to the user, or to provide 

the user with the option to update them.

Date and time: 

The server automatically updates the device with the 

current date and time.

Network notification messages:

 The server application can deliver 

customizable messages from the central monitoring system to the device.

Cybersecurity

It is the customer’s responsibility to ensure the security and integrity of its 
networks and systems, that its communication networks are configured to 
support encryption, and that those networks and systems are properly 
enabled, maintained, and utilized. 

The Cell Saver Elite/Elite+ device data that is transferred is encrypted using 
AES encryption. Additionally, the device allows you to configure the wireless 
connection to utilize WPA2 Personal and WPA2 Enterprise security protocol.

Wireless 
Connectivity

The Cell Saver

® 

Elite

®

/Elite

®

+ device is equipped with an internal wireless 

antenna and wireless module communication component that enable the 
device to communicate with an approved server application. Wireless 
technology provides the following benefits:

Enables the device to transmit procedure data electronically to an 
802.11a/b/g/n compatible wireless access point connected to the 
hospital’s wireless local area network (WLAN).

Transmits data in an encrypted standard format that may be used for 
electronic data collection and management by a central monitoring 
software system.

Allows for easier movement of devices in the hospital by eliminating the 
need for cabling.

Radio 
Equipment 
Specifications

The radio equipment specifications for the Cell Saver Elite/Elite+ device are as 
follows:

Wired 
Connectivity

If the device is not connected to the wireless network, it can communicate with 
the server application via an Ethernet connection. The Ethernet port is located 
on the bottom of the touch screen display.

Operating Frequency Band

Maximum Transmit 
Power

2412 to 2472 MHz

+15.5 dBm

5180 to 5825 MHz

+16.0 dBm

Summary of Contents for Cell Saver Elite

Page 1: ...Connectivity Upgrade User Manual Addendum 120857 US AC June 2017 0123...

Page 2: ...tain Haemonetics Corporation products This manual should be used in conjunction with instruction and training supplied by qualified Haemonetics personnel Any failure to follow the instructions as desc...

Page 3: ...onetics Corporation in the United States and or other countries Bluetooth is a registered trademark of Bluetooth SIG Inc QR Code is a registered trademark of Denso Wave Inc DELL and OptiPlex are trade...

Page 4: ......

Page 5: ...ctivity 7 Radio Equipment Specifications 7 Wired Connectivity 7 Network Setup and Maintenance 9 Wireless Network Setup and Maintenance 9 Creating a Network Configuration QR Code 9 Configuring the Devi...

Page 6: ...the end of the procedure The device must receive an acknowledgment from the server application before it marks the data as sent Status update messages The device sends messages to the server applicat...

Page 7: ...ol Wireless Connectivity The Cell Saver Elite Elite device is equipped with an internal wireless antenna and wireless module communication component that enable the device to communicate with an appro...

Page 8: ...sion AC Haemonetics Cell Saver Elite Elite User Manual Figure 1 Parts of the device display 2 6 4 1 3 5 7 1 Status beacon 2 Touch screen 3 Barcode reader laser aperture 4 STOP key 5 Touch screen mount...

Page 9: ...ss Relocate equipment change channels or follow wireless equipment manufacturer instructions to reduce or eliminate interference Cell Saver Elite Elite devices should be kept a minimum distance away f...

Page 10: ...e Haemonetics Customer Care Center to request access c Locate the CSEliteNetConfig Utility within the designated Cell Saver Elite product area d Click on CSEliteNetConfig Utility e Download the html f...

Page 11: ...ustomer Care Center by calling 800 537 2802 or by emailing productsupport haemonetics com Configuring the Device The Network Settings screen is password protected and you must have administrator acces...

Page 12: ...d by Network Connected and then Server Connected once it is connected to the server application 9 Touch Done to return to the System screen Note In the System screen you can also export or import netw...

Page 13: ...ce data transmission in the network using the Haemonetics HaemoCommunicator software as the data collection application The list is for reference only and is not intended to be a list of required equi...

Page 14: ...occurs between connected devices on the wireless network power off the router wireless access point for 30 seconds and then power it back on Parameter Value Model D LINK DIR 803 Channels Four 10 100 E...

Page 15: ...AC Ensure the wireless network router s provide enough capacity to connect to the server Haemonetics devices and other devices that may run at the same time Each of these will use a connection on the...

Page 16: ...Once the data is marked as sent the procedure record displays the date and time of export If the Cell Saver Elite Elite device is not connected to the server application the device automatically send...

Page 17: ...record will not be sent to the server application at the end of the procedure In this situation the Procedure Complete message and the status beacon will be yellow instead of green If you access the R...

Page 18: ...ng determining which fields appear in the Records screen and making a field mandatory Note You must have administrator level access in order to unlock the Options screen To make a field mandatory 1 To...

Page 19: ...hich will take several minutes Corrective Action Touch Install Update to install the software now or Touch Skip Update to skip the software installation This prompt will recur on the next power up 503...

Page 20: ......

Reviews: