English -
4
Description of the elements (Fig-1)
1
–
Towel rail 625*400mm
2
–
1x G1/2 air vent plug
3
–
Heater element
4
–
2x Bracket
ɸ
20.2x25
5
–
2x M6x20 screw
6
–
2x ST4.8x60mm screw
7
–
2x washer Ø16xØ6x1.4
8
–
2x Bracket
ɸ
28x34
9
–
2x Ø8x64mm wall plug
10
–
2x M5x12 fixing screw
Installation
1.
Installation must be carried out by a qualified professional or another fully qualified
person. It must be installed in accordance with the normal trade practices and in
compliance with the national legislation (EU electricity directives and regulations
concerning special installations and places of operation including bathrooms, shower
cabins (IEC 60364-7-701).
2.
Make sure you have the necessary equipment for your personal protection before
starting the installation.
3.
Check that you have prepared all the components indicated in the accessories box and
that the size and finish are what you need, before starting the installation.
4.
The improper installation, handling or use of the towel warmer will be an immediate
reason for the termination of the warranty offered for the product.
5.
The product can be safety installed in Zones 3. For installations in Zones 2 (check the
scheme below), please consider the following limitations:
•
In bathrooms, the product must never be installed in such a way that the control
panel may be touched by someone in the bathtub or having a shower. The control
panel should be located at least 600 mm distance from any wet areas. The body of
the product can be placed in Zones 2 if the control panel is located inside Zone 3.
•
In wet premises the power source must be installed at a height of at least 25 cm
above the floor (bathrooms and kitchens).
•
The product must be earthed.
IMPORTANT - This product must never be installed with its control panel at the
top. This product must not be installed horizontally. During installation, use
wedges so that the control panel will not be in contact with the floor.
Summary of Contents for Design Chrome TW-25C.005A