Hach sensION MM340 Manual Download Page 8

INSTRUMENT CONDITIONS

                        

  SN:70602  V1.0

Monday 30 July 2010 

15:50

------------------------------------------------------------------------
CHANNEL 1
Units...........................................................................................pH
Resolution.............................................................................0.01
Measurement..........................................................By stability
Criteria...........................................................................standard
Type of calibration ....................................Technical buffers
Frequency of calibration.....................................every 24 h.
CHANNEL 2
Units...........................................................................................ISE
Measurement..........................................................By stability
Criteria...........................................................................standard
Curve number...................................................................... 1, F-
Uniits measurement........................................................mol/l
Standard 1......................................................................0.00001
Standard 2........................................................................0.0001
Standard 3...........................................................................0.001
Standard 4.............................................................................0.01
Standard 5.............................................................................. 0.1 
SYSTEM
Stirrer number 2.................................................................. non
Codification............................................................. automatic
Data send .........................................................................printer
Type of printeri.............................................................thermal
Type of report..............................................................reduced
Samples by report........................................................ several
Readjust temperature.........................................................NO
------------------------------------------------------------------------

ELECTRODE HISTORY 

Channel 1

                        

  SN:70602  V1.0

Monday 30 July 2010 

15:50

------------------------------------------------------------------------
Installed : 

01-03-07 15:39:32

In service: 

06:30

Number of measurements: 

 216

 

Maximum value 

Minimum value

pH 

13.75 

1.15

mV 

-- 

--

T (˚C) 

38.2 

14.3

------------------------------------------------------------------------

MEASUREMENT DATA 

Channel 1

                        

  SN:70602  V1.0

Monday 30 July 2010 

15:50

Sample 

pH 

˚C 

Time 

St%

----------- 

---------- 

--------- 

----------  -------

15-03-07  14:36
38510 

10.15 

23.5 

00:15 

30 

15-03-07  14:40
38511 

9,85 

23.2 

00:22 

30

15-03-07  14:46
38512 

10.23 

22.8 

00:18 

30

16-03-07  08:36
Pozo1 

7.48 

23.1 

00:25 

30

------------------------------------------------------------------------

pH CALIBRATION DATA 

Channel 1

                        

  SN:70602  V1.0

Monday 30 July 2010 

15:50

------------------------------------------------------------------------
CALIBRATED     29-07-2010     15:42:51    22.5˚C
Buffers 

Slope  Sens 

P.Asym. 

Time

Technical 

mV/pH 

mV 

s

----------- 

----------  ----- 

---------- 

----------

4.01,7.00 

58.16  99.0 

-1.5 

18 

7.00,9.21 

57.91  98.5 

-1.5 

 

Stirring 30%

Calibration frequency,  every 24 h
------------------------------------------------------------------------

  
 

SYSTEM

10-04-2010   17:15

   

ISE MEASURE

  

   

10-04-2010   17:15

 

ISE CALIBRATION

  

   

10-04-2010   17:15

  DATA LOGGER  

10-04-2010   17:15

   

DATA LOGGER 

  

   

10-04-2010   17:15

  ... 

   

 Start pH measurement

 Channel 1

...by stability

Resolution: 0.01

Meas.: stability

View mV

Limits: no

Isopotential: pH 7

Measurement condit.

  Technical buffers

  DIN 19266 buffers

  User buffers

  To a X value

  Data introduction 

  Theoretical cal.

  Cal. frequency 

Calibration pH

  ...

  

  Start calibration  

  Channel 1

Technical bufferes

Consult 

  

Print

Erase

DATA LOGGER       C1

  ... 

   

Start measurement ISE

Channel 2

...curve 1

Curve no: 1

N. of decimals: 6

Measure: stability

Start ISE measurement  

Measurement condit.

Curve: 1

Units: mol/l

Name of Ion: F-

Standards: 5

1: 0.000010 mol/l

Factory settings

ISE Calibration 

  ...

  

  Start calibration  

  Channel 2

Curve 1

Consult 

  

Print

Erase

  Measurement units

  Sample ID

  Data output

  Type of report

  Users

DATA LOGGER       C2

SYSTEM

  

  Header

  Identify sensor

  Stirrer 2

  Date / Time

  Language

  Display contrast

  Readjust temp.

  Stirring

  Temperature units

Channel 1

Channel 2

Channel 2

Channel 2

Channel 1

  

pH CALIBRATION

  

Channel 1

10-04-2010   17:15

   

pH MEASURE 

  

   New CAL in 12 h

10-04-2010   17:15

Technical Buffers

Use first buffer

Continue...

CALIBRATING pH 

Technical Buffers

Use second buffer

Continue...

CALIBRATING pH 

Technical Buffers

Use third buffer

Continue...

CALIBRATING pH 

  ...

  

  Start calibration  

  Channel 1

Technical buffers

1st buffer OK

pH 7.01          23˚C

00:30

CALIBRATING 

1st buffer

pH

 7.15          25˚C

 

 

 

   00:23

CALIBRATING 

1st buffer

pH

 7.15          25˚C

Stirring

  23%

   00:23

CALIBRATING 

2nd buffer

pH

 4.12          23˚C

00:20

2nd buffer OK

pH 4.01          23˚C

00:26

Channel 1

  

pH CALIBRATION

  

10-04-2010   17:15

CALIBRATING 

1st buffer

pH 7.15          

25˚C

00:23

4. Operation

Example of report

Notes:

1. 

Channel 1 and Channel 2 can measure pH, mV or ISE with no difference . 
Measuring units can be selected in System , seer page 17 .

2.

  The system configuration, sample codification, data output, type of report, 

etc, are common parameters for the two channels .

3.

  Data  Logger .  The  measurements  will  be  stored  in  the  Data  Logger  of  the 

corresponding channel .

4.4. General diagram

This is a general view over the way to access to all possibilities of the instrument:

7

ENGLISH

Note:

 

The 

 sign on the  

display indicates flashing.

Channel 1

Channel 2

Summary of Contents for sensION MM340

Page 1: ...ACH Company 2010 All rights reserved Printed in Spain Manual Manual Manual de instru es Manuel d utilisateur 07 2010 Edition 1 07 2010 Edici n 1 07 2010 Edi o 1 07 2010 Edition 1 2010 7 DOC022 97 9025...

Page 2: ...libration 8 4 6 Other options for calibration 9 4 7 pH measurements 10 4 8 Re programming pH measurement 11 4 9 Printing data of pH measurements 12 4 10 mV measurements 14 4 11 Ion selective measureme...

Page 3: ...7 F Calibration at any mV value Manual introduction of the calibration parameters ISE calibration 2 to 5 programmable standards Selectable calibration units mol l M g l mg l ppm mmol l mM mol l or Up...

Page 4: ...d lead to damage to the instrument Important information that requires special emphasis Note Information that supplements points in the main text 2 1 2 Precautionary labels Read carefully all labels a...

Page 5: ...ure 3 Drive the stick into the hole 4 Turn the shift in a counterclockwise until the stick is well fixed Place the o ring at 135 140 mm from the base in order to avoid the shock of the sensor against...

Page 6: ...ctor 11 Plug in power supply 12 V 3 2 Connections DANGER Make sure the power adapter matches your local power supply 4 1 Description Keys Switch on Switch off Confirms the option displayed When there...

Page 7: ...ution 0 01 pH Measurements By stability with standard criterion In continuous pressing twice the key Calibration in 1 2 or 3 points with technical buffers Calibration frequency every 24 hours Channel...

Page 8: ...DIN 19266 buffers User buffers To a X value Data introduction Theoretical cal Cal frequency Calibration pH Start calibration Channel 1 Technical bufferes Consult Print Erase DATA LOGGER C1 Start measu...

Page 9: ...en measuring pH values similar to those of the buffer solution It corrects the asymmetry potential of the electrode Two point calibration This is the most common calibration It is recommended to start...

Page 10: ...06 6 865 7 000 9 180 10 012 and 12 454 User s buffers Suitable when the two above mentioned options will not be used The sensION MM340 allows introducing the table pH Temp for the desired buffers See...

Page 11: ...01 MEASURING continuous Channel 1 pH MEASURE New CAL in 12 h 10 04 2010 17 15 4 Operation 4 7 pH measurements Measurement by stability This is the default measuring mode for the sensION MM340 Meanwhi...

Page 12: ...art Measurement Channel 1 by stability 10 04 2010 17 15 Channel 1 pH MEASURE New CAL in 12 h Default programming standard Other options Resolution 0 01 pH 0 1 pH 0 01 pH 0 001 pH Measuring mode By sta...

Page 13: ...ion frequency 24 h SYSTEM SYSTEM Measurement units Sample ID Data output Measurement units Sample ID Data output SYSTEM Data output Deactivated For printer For computer SYSTEM Data output Deactivated...

Page 14: ...ial number 7890 pHiso pH 7 pH 7 00 CALIBRATED 14 02 2010 08 50 37 Technical Sens A P T t St Buffers mV C s 4 01 7 00 100 3 0 1 25 6 25 CONDITIONS CHANNEL 1 STABILITY MEASUREMENTS STANDARD CRITERIA Sam...

Page 15: ...hannel 2 ISE Data Time 04 06 2010 09 30 Monday SYSTEM Codification Automatic Manual SYSTEM Measurement units Sample ID Data output SYSTEM Measurement units Channel 1 pH Channel 2 ISE Save changes SYST...

Page 16: ...CALIBRATION 10 04 2010 17 15 4 Operation 4 11 Measurement with ion selective electrode Curve number 1 sensION MM340 can store in memory up to 4 calibration curves for each channel Measurement by stab...

Page 17: ...Minimum value pH 13 75 1 15 mV T C 38 2 14 3 MEASUREMENT DATA Channel 1 SN 70602 V1 0 Monday 30 July 2010 15 50 Sample pH C Time St 15 03 07 14 36 38510 10 15 23 5 00 15 30 15 03 07 14 40 38511 9 85...

Page 18: ...Display contrast SYSTEM Stirring Stirrer N 1 OFF 25 ON SYSTEM Stir Stirrer N 1 ON 25 OFF SYSTEM Readjust temp Stirring Temperature units SYSTEM Temperature units Celsius Fahrenheit SYSTEM ENGLISH GER...

Page 19: ...bration pH 4 Operation 4 14 Temperature readjustment The sensION MM340 allows the correction of the deviation presented by a temperature probe integrated in the electrode or separated sensor at 25 and...

Page 20: ...compensation in the measurements Example for electrode behavior a Electrode calibration line at room temperature b A calibration line with pHiso 7 to apply when measure at 70 C 158 F c Real calibratio...

Page 21: ...the printer reports see pages 12 and 13 They can be exported to an Excel program as well See PC connection cables at page 21 Replacement parts Data sending to PC ComLabo software ComLabo PN LZW8999 99...

Page 22: ...00 s Check temperature Check the electrode MEASURING by stability pH out of range Check the electrode MEASURING by stability out of range C Check temp sensor MEASURING by stability MEASURE STABLE pH 1...

Page 23: ...any repair or attempted repair not authorized by Hach Company Any product not used in accordance with the instructions furnished by Hach Company Freight charges to return merchandise to Hach Company F...

Page 24: ...o hach lange nl www hach lange nl HACH LANGE APS kandevej 21 DK 2700 Br nsh j Tel 45 36 77 29 11 Fax 45 36 77 49 11 info hach lange dk www hach lange dk HACH LANGE AB Vinthundsv gen 159A SE 128 62 Sk...

Reviews: