on page 11. The temperature program is selected
independently for each heating block when there are two heating
blocks.
Note: To stop a program, push the key below the program two times.
LT 200: The digestion program starts. The temperature of the
heating block increases to the selected temperature, then the time
automatically counts down to zero (0). When the digestion program
is completed, three beeps are heard and the heater turns off.
DRB 200: The temperature of the heating block increases to the
selected temperature.
8.
DRB 200: When the heating block is at the selected temperature
(two beeps are heard), put the test sample cells in the correct
heating block and close the protective cover. Push
Start
to start the
digestion program.
When the digestion program is completed, three beeps are heard
and the heater turns off.
6.2 Stored programs
provides descriptions of the stored temperature programs for the
provides descriptions of the stored temperature
programs for the DRB 200.
Table 3 Stored programs—LT 200
Program Description
COD
Increases the temperature of the sample cells to 148 °C for
120 minutes. In the cooling phase, four beeps are heard
when the sample cells are at 80 °C. Remove and carefully
invert the sample cells several times, before letting them
decrease in temperature in a rack.
The COD temperature program can be used for all COD
sample cell tests.
100 °C
Increases the temperature of the sample cells to 100 °C for
10, 60 or 120 minutes.
For example, the “100 °C, 60 minutes” temperature
program is used to:
• Identify phosphate and chromium
• Digest heavy metals
• Digest samples using the LCW 902 Crack Set
40 °C
Increases the temperature of the sample cells to 40 °C for
10 minutes.
For example, the “40 °C, 10 minutes” temperature program
is used for formaldehyde test or enzymatic food tests.
Table 4 Stored programs—DRB 200
Program Description
COD
Increases the temperature of the sample cells to 150 °C for
120 minutes. In the cooling phase, four beeps are heard
when the sample cells are at 120 °C. Remove and carefully
invert the sample cells several times, before letting them
decrease in temperature in a rack.
TOC
Increases the temperature of the sample cells to 105 °C for
120 minutes. The TOC temperature program can be used
for all Hach TOC sample cell tests.
English
11
Summary of Contents for LT 200
Page 3: ...260 3...
Page 7: ...1 2 English 7...
Page 18: ...1 2 18 Deutsch...
Page 29: ...1 2 Italiano 29...
Page 40: ...1 2 40 Fran ais...
Page 51: ...1 2 Espa ol 51...
Page 62: ...1 2 62 Portugu s...
Page 73: ...1 2 e tina 73...
Page 84: ...1 2 84 Dansk...
Page 95: ...1 2 Nederlands 95...
Page 106: ...1 2 106 Polski...
Page 117: ...1 2 Svenska 117...
Page 128: ...1 2 128 Suomi...
Page 137: ...2 1 2 1 1 2 1 2 T 2 2 137...
Page 138: ...1 LT 200 DRB 200 1 1 3 5 2 4 3 3 1 138...
Page 139: ...1 2 139...
Page 140: ...4 4 1 2 2 1 3 2 4 4 2 3 1 5 2 6 3 7 4 140...
Page 141: ...1 5 5 1 20 1 2 3 4 141 5 2 1 2 3 2 2 GB Bulgarian E D NL F S I PL 5 3 1 2 3 OK 6 MSDS SDS 141...
Page 142: ...EMI 20 cm 7 9 in 20 7 9 6 1 80 C 80 C 144 142...
Page 150: ...1 2 150 Magyar...
Page 161: ...1 2 Rom n 161...
Page 172: ...1 2 172 lietuvi kalba...
Page 181: ...2 1 2 1 1 2 1 2 181...
Page 182: ...2 2 1 LT 200 DRB 200 1 1 3 5 2 4 3 3 1 182...
Page 183: ...183...
Page 184: ...1 2 184...
Page 185: ...4 4 1 2 2 1 3 2 4 4 2 3 1 5 2 6 3 7 4 185...
Page 186: ...1 5 5 1 20 1 2 3 4 186 5 2 1 2 3 2 2 GB E D NL F S I PL 5 3 1 2 3 OK 6 MSDS SDS 186...
Page 187: ...20 20 7 9 6 1 80 C 80 C 187...
Page 190: ...1 2 Prog 3 4 OK 4 37 150 C OK 5 0 480 OK 6 OK 7 7 1 1 2 1 2 3 4 5 190...
Page 196: ...1 2 196 T rk e...
Page 207: ...1 2 Slovensk jazyk 207...
Page 218: ...1 2 218 Slovenski...
Page 229: ...1 2 Hrvatski 229...
Page 238: ...2 1 2 1 1 2 1 2 2 2 1 238...
Page 239: ...LT 200 DRB 200 1 1 3 5 2 4 3 3 1 239...
Page 240: ...1 2 240...
Page 241: ...4 4 1 2 2 1 3 2 4 4 2 3 1 5 2 6 3 7 4 241...
Page 242: ...1 5 5 1 20 1 2 3 4 242 5 2 1 2 3 2 2 Language Language GB E D NL F S I PL 5 3 1 2 3 242...
Page 243: ...6 MSDS SDS EMI 20 cm 7 9 20 7 9 6 1 80 C 80 C 243...
Page 246: ...1 2 Prog 3 4 4 37 150 C 5 0 480 6 7 7 1 1 2 1 2 3 4 5 7 2 246...
Page 252: ...1 2 252 eesti keel...
Page 263: ...1 2 263...
Page 271: ......