![Hach DR2400 Manual Download Page 26](http://html1.mh-extra.com/html/hach/dr2400/dr2400_manual_3229295026.webp)
General Instrument Operation
General Instrument Operation
Page 26
5940018Operation.fm
2.6
Sample Cell Adapters
CAUTION: Do not
place vials that are
hotter than 100 °C
(212 °F) into any of
the sample cell
adapters.
ATENCIÓN: No colocar cubetas cuya temperatura sea superior a 100 °C (212 °F)
sobre los soportes de muestra.
VORSICHT: Die Küvettentemperatur darf beim Einsetzen in die Küvettenhalter
nicht mehr als 100°C (212 °F) betragen.
PRUDENCE: Ne placez pas de cuve de plus de 100°C (212°F) dans un des
porte-cuves d'échantillon.
The DR/2400 Portable Spectrophotometer holds a 1 inch (25.4 mm) diameter
round cell or an AccuVac® Ampul without an adapter. The 16-mm cell adapter
(Cat. No. 59457-00) is used with Test ‘N Tube™, Chemical Oxygen Demand,
Total Organic Carbon, and UniCell procedures. Immunoassay tests and other
procedures using the 1-cm square cell require the square cell adapter
(Cat. No. 59459-00). See
. Tests requiring the multi-pathlength cell
(Cat. No. 59405-00) or Pour-Thru Cell Kit (Cat. No. 59404-00) require the use of
the multi-pathlength cell adapter (Cat. No. 59466-00).
2.6.1
Installing Sample Cell Adapters
To place a cell adapter into the instrument, align the tabs on the adapter with the
alignment recesses in the round-cell holder. Turn the adapter clockwise until the
alignment marks on the adapter line up to the base alignment marks on the
instrument. The adapter will snap into place. Place the sample cell into the cell
adapter. For best results, use only the sample cells recommended in the Hach
procedures.
Remove an adapter by turning it counter-clockwise until the tabs are aligned
with the grooves and the adapter slides out easily.
Figure 9
Cell Adapters
!
!
TOC and UniCell Adapter (Cat. No. 59457-00)
Alignment
Tab
Alignment
Tab
Base
Alignment
Recess
Alignment
Mark
Base
Alignment
Mark
Multi-pathlength
Cell and Pour-Thru
Cell Adapter
(Cat. No. 59466-00)
Cell Cap
(Cat. No. 59413-00)
Alignment
Rib
Alignment
Rib
Light Path
Window
(1 cm)
Alignment
Tab
Multi-pathlength Cell
(Cat. No. 59405-00)
1-cm Square Cell Adapter (Cat. No. 59459-00)
Alignment
Mark
Alignment
Tab
Light Path
Window
(1 in.)
Summary of Contents for DR2400
Page 2: ...Page 2 5940018Title fm...
Page 6: ...Page 6 5940018TOC fm...
Page 8: ...Page 8 5940018Safety fm...
Page 10: ...Page 10 5940018Spec fm...
Page 12: ...Page 12 5940018InstStop fm...
Page 20: ...Page 20 5940018Getting Started fm...
Page 32: ...Page 32 5940018Operation fm...
Page 46: ...Page 46 5940018StdAdd fm...
Page 48: ...Page 48 5940018SingleWave fm...
Page 50: ...Page 50 5940018MaintStop fm...
Page 56: ...Page 56 5940018Troubleshoot fm...
Page 58: ...Page 58 5940018GenInfo fm...