Specification
Details
Sample volume accuracy
(typical)
±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of
3
/
8
-
in. vinyl intake tube, single bottle, full bottle shut-off at room temperature and
1524 m (5000 ft) elevation
Sampling modes
Pacing: Fixed Time, Fixed Flow, Variable Time, Variable Flow, Event
Distribution: Samples per bottle, bottles per sample and time based (switching)
Run modes
Continuous or non-continuous
Transfer velocity (typical)
0.9 m/s (2.9 ft/s) with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of
3
/
8
-in. vinyl intake
tubing, 21 °C (70 °F) and 1524 m (5000 ft) elevation
Liquid detector
Ultrasonic. Body: Ultem
®
NSF ANSI standard 51 approved, USP Class VI
compliant. Contacting liquid detector or optional non-contact liquid detector
Air purge
An air purge is done automatically before and after each sample. The sampler
automatically compensates for different intake tube lengths.
Tubing
Intake tubing: 1.0 to 30.0 m (3.0 to 99 ft) length, ¼-in. or
3
/
8
-in. ID vinyl or
3
/
8
-in.
ID Teflon
™
-lined polyethylene with protective outer cover (black or clear)
Wetted materials
Stainless steel, polyethylene, Teflon, Ultem, silicone
Memory
Sample history: 4000 records; Data log: 325,000 records; Event log:
2000 records
Communications
USB and optional RS485 (Modbus)
Electrical connections
Power, auxiliary, optional sensors (2x), USB, distributor arm, optional rain
gauge, thermal (AWRS only)
Analog outputs
AUX port:
none;
optional IO9000 module
: Three 0/4–20 mA outputs to supply
the recorded measurements (e.g., level, velocity, flow and pH) to external
instruments
Analog inputs
AUX port:
One 0/4–20 mA input for flow pacing;
optional IO9000 module
: Two
0/4–20 mA inputs to receive measurements from external instruments (e.g.,
third-party ultrasonic level)
Digital outputs
AUX port:
none;
optional IO9000 module
: Four low voltage, contact closure
outputs that each supply a digital signal for an alarm event
Relays
AUX port:
none;
optional IO9000 module
: Four relays controlled by alarm
events
Certifications
CE, cETLus
English
5
Summary of Contents for AS950 AWRS
Page 2: ...English 3 Fran ais 27 Espa ol 52 Portugu s 77 102 124 2...
Page 22: ...22 English...
Page 47: ...Fran ais 47...
Page 72: ...72 Espa ol...
Page 97: ...Portugu s 97...
Page 105: ...1 AWRS 105...
Page 106: ...106...
Page 108: ...2 AWRS 1 6 11 2 7 12 3 8 13 4 9 AWRS 14 5 10 86 kg 190 lb 90 kg 198 lb 3 108...
Page 110: ...4 AWRS 1 2 2x 111 5 5 110...
Page 111: ...1 6 8 2 8 6 1 24 1 L 4 8 24 7 2 24 350 mL 5 8 AWRS 3 6 9 1 7 PE 2 8 PE 111...
Page 112: ...3 9 102 7 8 112...
Page 113: ...9 1 2 3 GFCI GFI 15 A AWRS 5 10 113...
Page 116: ...pH 12 12 5 POWER POWER AWRS 116...
Page 117: ...13 1 13 2 3 4 5 O 6 13 1 3 O 2 4 117...
Page 118: ...4 6 m 15 2 m 15 ft 50 ft 1 2 14 3 4 5 14 1 7 2 8 AWRS 3 9 4 10 5 11 AWRS 6 12 AWRS 118...
Page 119: ...119...
Page 120: ...118 120...
Page 122: ...16 16 2 2 2071 4652 118 122...
Page 123: ...2 2071 4652 123...
Page 127: ...1 AWRS Web 127...
Page 128: ...128...
Page 130: ...2 AWRS 2 AWRS 2 AWRS 1 6 11 2 7 12 3 8 13 4 9 AWRS 14 5 10 86 Kg 90 kg 3 HACH Japan 130...
Page 131: ...3 1 5 AWRS 2 6 3 7 4 8 3 2000 m 2 000 m AWRS 124 1 127 AWRS 3 8 4 1 2 14 NPT 3 131...
Page 132: ...4 AWRS 1 2 2 1 133 5 5 132...
Page 133: ...1 6 8 1 2 8 6 1 24 x 1 L 4 8 24 7 2 24 x 350 mL 5 8 AWRS 3 1 6 9 133...
Page 134: ...1 7 PE 2 8 PE 3 9 124 7 134...
Page 135: ...8 9 1 2 3 GFCI GFI 135...
Page 139: ...1 4 6 90 18 V 2 200 mA DC 18 VDC 7 RF RF AC AUX I O 3 m 7 12 12 5 POWER POWER AWRS 2 139...
Page 140: ...13 1 13 2 3 4 140...
Page 141: ...5 O 6 13 1 3 O 2 4 4 6 m 15 2 m 1 2 14 3 4 5 141...
Page 142: ...14 1 7 2 8 AWRS 3 9 4 10 5 11 AWRS 6 12 AWRS 142...
Page 143: ...143...
Page 144: ...141 144...
Page 145: ...1 2 4 8 mm 19 mm 15 1 3 4 15 1 4 152 4 mm 177 8 mm 190 8 mm 7 2 5 3 6 145...
Page 146: ...16 16 2 2 AC 146...
Page 147: ...2 2071 4652 141 2071 4652 147...
Page 148: ......
Page 149: ......