Hach Ultra ORBISPHERE 511 Quick Manual Download Page 14

Page 14

Services

A number of maintenance and diagnostic options
are available from the 

Services

 menu.

Sensor Diagnostics - Calibration Timer

The instrument can automatically remind the user
when the next sensor calibration is due. Select
the channel, enable it and enter a delay in days.
The display shows current instrument date and
time, next calibration due date and time, and the
remaining days. 
The next calibration date is updated when the
sensor is calibrated. 

Sensor Diagnostics - Service Timer

The instrument can automatically remind the user
when the next sensor service is due. Select the
channel, enable it and enter a delay in days. The
display shows current instrument date and time,
next calibration due date and time, and remaining
days.
The next service date is updated when the button

Service done

 is pressed after a service. 

The sensors attached to your instrument will
require periodic servicing and maintenance. For

more information on this, please refer to the
manual(s) delivered with your sensor(s).

Language

Check the language as required and restart the
instrument to apply the change. The instrument
will restart in the selected language. 

Other Options

These include:

Time/Date

 - Used to set the time, date 

and the display settings

Screen

 - Used to set the screen contrast

Buzzer

 - Used to set the alarm 

parameters (sound, volume, etc.)

Main board info

 - Displays instrument 

model, ID and software version

Batteries

 - On all instruments this 

display gives the real time clock battery 
charge level and voltage. On portable 
instrument there is a battery level 
indicator for the main batteries.

Instrument Maintenance

Any instrument maintenance should be carried
out by a qualified Hach Ultra Service Technician.
Please contact your local representative should
yo u f ee l an y ma in te na nc e o r in st ru m en t
adjustments are required.

Troubleshooting - List of Events

The possible events, along with the text message
displayed on the instrument numeric view screen,
the reason for the event and its criticality are listed
in the following table. 

Maintenance and Troubleshooting

Summary of Contents for ORBISPHERE 511

Page 1: ...Operator Quick Guide ORBISPHERE 510 511 512 Revision G 05 11 2008...

Page 2: ...d service routines can be called by pressing buttons and menus bar on screen Measurement display shows one measurement slope per sensor in function up to 3 lines for a 3 channel Orbisphere 51x Special...

Page 3: ...s measured and the channel configuration The statistical view offers statistical data that matches with Total Quality management tools Statistics is a tool to better analyze how a process behaves The...

Page 4: ...concentration is smaller than that entered in Variation Time The stop criteria is met when the elapsed time reaches the Max time parameter The parameter Max time is the maximum time allowed to reach...

Page 5: ...arms Set this to a minimum but enough to avoid alarms for non representative peaks beyond the set level Measurement Filter Configuration The filters are aimed at flattening the measurement curve in si...

Page 6: ...actor Enable correction as appropriate If checked the percentage correction factor must be entered This value cannot be negative Note To manually set the TC sensor into a continuous purge mode press t...

Page 7: ...from the non volatile memory Adjust the parameters for recording and storing measured data Two storage mode selections are available depending on the measurement mode selected Continuous measurement m...

Page 8: ...ation of the Measured Gas Before initiating a calibration process the calibration parameters must be set by pressing on the Modify button Last calibration parameters are memorized so this step can be...

Page 9: ...intenance Manual for details Verification Similar to the calibration procedure but for verification of the actual calibration values The result of the measurements made during the verification is not...

Page 10: ...the Measured Gas Before initiating a calibration process the calibration parameters must be set by pressing on the Modify button The last calibration parameters are memorized so this step can be igno...

Page 11: ...e variation indicates the variation during the last 3 measurements which is the stability of the measurements A variation as low as possible is needed for a precise calibration The display shows the a...

Page 12: ...iate the H2 interference calibration Interference Calibration TC Sensor This calibration is available for TC sensors and is required when one of the interferences has been enabled The lower part of th...

Page 13: ...point calibration recommended One point calibration By default the two point calibration is selected Two Point Calibration recommended Connect a certified absolute pressure gauge to the sample line a...

Page 14: ...e information on this please refer to the manual s delivered with your sensor s Language Check the language as required and restart the instrument to apply the change The instrument will restart in th...

Page 15: ...tration is below the Alarm LowLow limit Alarm low The gas concentration is below the Alarm Low limit Alarm high The gas concentration is above the Alarm High limit Alarm high high The gas concentratio...

Page 16: ......

Reviews: