HACE MJS-500 Instruction Manual Download Page 6

PROBLEM

CAUSE

SOLUTION

Standby indicator isn’t working, 

no wind; no mist.

Water-short indicator on; 

no wind; no mist

Mist with abnormal smell

Mist generation abnormal

Abnormal noise

Water not used

Power not connected

Short of water

New appliance /

Dirty water

The transducer begrimed 

Dirty water or the water left too 

long

Too much water in the gutter

Resonate between the appliance 

and the layer

The dirty cover of the tank or 

the tank not put properly

Connect the power plug

Fill with water in the tank

Open the tank and put the mouth 

of the tank in shade for 12 hours 

Clean the tank and replace with 

clean water

Clean the transducer

Clean the tank and replace with 

clean water.

Reduce some water and re-fix 

the cover of tank

Put the appliance on a firm layer

Clean the cover and put the tank 

on right place

WARNING!

Should up mentioned solutions do not work please contact the manufacturer or agent. Do never arbitrarily 

disassemble, repair or restructure the apparatus. If there are some differences between the pictures showed 

in the instruction manuals and the real products, please refer to the real products. Excuse us that we can’t 

inform you if there are changes to the specifications of the products. ZHANGZHOU WANLIDA PHOTO

-

CATALYSIS SCIENCE - TECHNOLOGY CO.LTD owns the right of final explanation.

Distributer:

TES Scandinavia AB

Krokslätts Fabriker 30

431 37 Mölndal - Sweden

Tel. +46 (0)31-761 36 10

Fax. +46 (0)31-87 34 00

www.tesscandinavia.se

[email protected]

6. Troubleshooting

Summary of Contents for MJS-500

Page 1: ...Instruction manual Ultrasonic Humidifier HACE MJS 400 HACE MJS 500 ...

Page 2: ...eft unused for a long time Never drain water from the gutter before disconnecting the power otherwise transducer will be de stroyed Do not pour the water over 40o into the tank otherwise the color or shape may be changed To make sure the humidifier work well and avoid accidents please choose carefully the places where you put the humidifier a Where plain and firm b Where far from heat resources or...

Page 3: ...t while the mist setting is S2 Turn off by pressing the On Off button again 4 Mist control There are four settings S1 S2 S3 S4 The display shows the setting at first and water flow later If you set the mist during humidifying the humidifying will be stopped 5 Humidifying Range of humidity setting from 40 to 70 RH One press 1 added One long press 5 added The humidifying stops when the environmental...

Page 4: ...Environmental temperature and set hours display 15 Mist settings and water flow indicator MJS 500 1 Handle 2 Air flow outlet 3 Tank 4 Cover 5 Power switch 6 Power cord 7 Main body 8 Display 9 Humidity setting 10 Timer 11 Mist 12 ON OFF 13 Window for humidity sensor 14 Environmental humidity and set humid ity display 15 Set hours display 16 no used 17 Water short 18 Work indicator 19 Standby indica...

Page 5: ...inished 5 Please take out the water filter and keep it dry if the humidifier is going to be left unused for a long time 4 Suggestions Humidifying with tap water or distilled water Clean the transducer tank and main body every week Replace the water frequently to keep the water clean Keep the tank and gutter dry if the humidifier is going to be left unused for a long time Keep all parts of humidifi...

Page 6: ...he tank and replace with clean water Reduce some water and re fix the cover of tank Put the appliance on a firm layer Clean the cover and put the tank on right place WARNING Should up mentioned solutions do not work please contact the manufacturer or agent Do never arbitrarily disassemble repair or restructure the apparatus If there are some differences between the pictures showed in the instructi...

Reviews: