IV. FIRST START-UP OF HEATERS

1.  Unpack the heater, take out the tank and all information materials. Place the device in a well-ventilated 

room, on a heat-resistant area.

2.  Make sure that you have received the heater in the 230 V version (information on the bottom of the 

device).

3.  When using the device for the first time, after it is warmed up, it is natural for the elements to smoke, 

because they are exposed to high temperature for the first time. Therefore it is necessary to ensure 
good ventilation in the room. Please follow the steps below:

 

Place the device in a well-ventilated room on a heat-resistant area.

 

Remove the cover and the water tank.

 

Set the controller to the maximum temperature range (clockwise).

 

Let the device smoke for about an hour or more.

4.  Smoke is normal during the first heat-up and will not occur during next treatments.
5.  When the smoke stops, disconnect the device from the power supply and let it cool down.

V. USE OF HEATERS

1.  Wash all stones before first use and after each treatment.
2.  Place a towel on the bottom of the tank and place the stones on it.
3.  Before connecting the device to the power supply, pour water into the tank so that the stones are 

covered, but not more than 2.5 cm below the top of the tank. Cover the tank with a lid.

4.  Connect the device to the power supply, turn the regulator fully (clockwise) to 20 up to 30 minutes to 

speed up heating. When the water heats up, turn the knob to hold requsted temperature.

5.  The control lamp is on when the heater is operating and will automatically turn off when the device 

reaches the required temperature or if the device is disconnected from the power supply.

6.  Carefully remove the first stone from the tank, check its temperature with your finger and then grasp it 

with your hand. The stone should be visibly warm, but cannot burn and be uncomfortable for the 
patient.

7.  After finishing the treatment, turn the regulator fully anti-clockwise to turn off the device.
8.  Never put stones directly into the heater as it may cause device damage.
9.  Be careful when putting in, taking out and moving the stones inside the heater.
10.  Do not apply stones on the flushed area of the body.
11.  Hot stones must never be placed on wounds, burns, abrasions, especially on the sensitive skin or 

damaged skin in any way.

VI. MAINTENANCE AND CLEANING OF HEATERS

1.  Clean the device after each treatment.
2.  Before cleaning, set the temperature control to the minimum setting. Disconnect the device from the 

power supply.

3.  Allow device to cool down to room temperature.
4.  Remove the stones carefully and then pour out the water.
5.  Clean the tank and cover with water and a little soap, then rinse with clean water and dry towel.
6.  Wipe the heater with a soft cloth. Never immerse the heater in water.
7.  Clean the stones with warm water and a little soap or other mild detergent. Rinse stones with warm 

water and dry.

VII. APPLICATION OF STONES

  Basalt is the most common type of stone used in hot stone therapy. Free from pores, with a smooth 

surface, it has unique holding warm properties. The high amount of rust in basalt accelerates the treatment 
of vascular diseases blood vessels, has a relaxing effect on the muscular and mood improvement.

8

Summary of Contents for 17l

Page 1: ...that the proper use and maintenance of the products ensures full satisfaction of their use for many years Dzi kujemy Pa stwu za wyb r produkt w HABYS i gratulujemy udanego zakupu Przypominamy e prawid...

Page 2: ...okonywanie zmian w urz dzeniu mo e prowadzi do po aru lub pora enia elektrycznego 11 Urz dzenie powinno by u ytkowane w pomieszczeniach zamkni tych 12 Kabel zasilaj cy nie powinien zwisa ze sto u lub...

Page 3: ...ia odkr maksymalnie regulator zgodnie ze wskaz wkami zegara na 20 do 30 min eby przy pieszy podgrzewanie Kiedy woda nagrzeje si zakr pokr t o aby utrzyma po dan temperatur 5 Lampka kontrolna wieci si...

Page 4: ...z instrukcj u ytkowania podgrzewacza 3 Temperatura kamieni powinna wynosi oko o 50 C 4 Po ka dym zabiegu nale y op uka kamienie pod bie c zimn wod nast pnie nale y umy je ciep wod z dodatkiem myd a i...

Page 5: ...i cych substancjach t uszczach kremach balsamach lub olejach trwa ego zabarwienia rodkami barwi cymi takimi jak tusze permanentne markery czy inne nietrwa e barwniki stosowane w produkcji odzie y np b...

Page 6: ...przekracza a cen Sprz tu wskazan w dowodzie jego zakupu Nabywcy w ramach gwarancji nie przys uguje danie wymianu Sprz tu na nowy Gwarancja w szczeg lno ci nie obejmuje odpowiedzialno ci za straty lub...

Page 7: ...with a damaged cord or plug 10 Modifications to the device may result in fire or electrocution 11 The device should be used indoors 12 The power cord should not hang over the table or touch hot surfac...

Page 8: ...operating and will automatically turn off when the device reaches the required temperature or if the device is disconnected from the power supply 6 Carefully remove the first stone from the tank check...

Page 9: ...ld by the Manufacturer or a service indicated by the Manufacturer and held by its Distributor e Equipment refers to a movable item manufactured by the Manufacturer being the subject of the sales and t...

Page 10: ...rantee card or to the address of the Authorized Service Centre d designation of the place where the Manufacturer delivers the equipment after repairing it limited to the country in which the Equipment...

Page 11: ...t Ovular Stone 3x4x1 8 cm 6 szt Eliptyczne ma e Miniature Pressure Point Stone 3x4x0 8 cm 8 szt 8 szt 8 szt W kszta cie walca Contoured Ovular Facial Stone 3x8x1 8 cm 4 szt 2 szt Do pracy z czakrami C...

Page 12: ...YS Sp z o o ul Produkcyjna 16 38 200 Jas o PL tel 48 887 766 115 info habys pl www habys pl Inne wersje j zykowe dost pne pod adresem Other language versions available here www habys com warrantymanua...

Reviews: