HABONIM C47C Installation, Operating, Maintenance Download Page 1

Installation, Operating & Maintenance 

Cryogenic Valves Series  

  

WARNINGS & SAFETY INSTRUCTIONS

Habonim cannot anticipate all of the situations a user 
may encounter while installing and using Habonim 
valves. The user MUST know and follow all applicable 
industry specifications on the safe installation and use of 
these valves. Misapplication of the product may result in 
injuries or property damage. Refer to Habonim product 
catalogues, product brochures and installation, operating 
and maintenance manuals for additional product safety 
information  or  contact  Habonim  technical  service.

1. 

 Keep hands and objects away from the valve ports at 
all times. Actuated valves could be accidentally 
operated, resulting in serious injury or valve damage.

2. 

Before removing a valve from the line always make 
sure the line has been depressurized and   drained.

3. 

 Utmost caution must be taken when handling a valve 
that has toxic, corrosive, flammable or a contaminant 
nature media flowing through its pipeline. The 
following safety precautions are recommended when 
dismantling valves with hazardous media: 
a.  Wear eye shield, protective headgear, clothing,

gloves and footwear.

b.  Have available running water. 
c.  Have a suitable fire extinguisher when media is

flammable.

4. 

 Do not try to operate a valve that exhibits any sign of 
leakage. Isolate the valve and either repair or replace it.

5. 

 Do not use or substitute non Habonim components or 
parts in Habonim valves and assemblies.

1. GENERAL

This Installation, Operating & Maintenance manual covers the 
instructions required for safe use of Habonim cryogenic ball valve.
Before using a valve, read the entire IOM carefully and make sure 
you understand everything.     

C47C, FC47C, FC47W 

Fire-Safe (FC) and non Fire-Safe

Sizes included:

½” - 6” (DN15 - DN150)

Habonim ISRAEL

Tel: +972-4-6914911 / 6914903

Fax: +972-4-6914935

[email protected]

Habonim USA

Toll Free Phone: 1-866-261-8400

Toll Free Fax: 1-866-243-9959

[email protected]

Habonim China

Tel: + 86 21 64453190 *146

Fax: + 86 21 64453191

[email protected]

Habonim UK

Tel: +44-1633-484554

Fax: +44-1633-482252

[email protected]

Habonim Australia

Tel: +61 3 9556 5428

[email protected]

H-C47C-02/17

Inspired By Challenge

Summary of Contents for C47C

Page 1: ...owing safety precautions are recommended when dismantling valves with hazardous media a Wear eye shield protective headgear clothing gloves and footwear b Have available running water c Have a suitabl...

Page 2: ...afe use of the valves and the particular performance requirements for the application This information can be found on the nameplate welded to the valve body The combined corrosion and erosion allowan...

Page 3: ...the upstream port of the valve as indicated by the arrow The stem head has an engraved T mark identifying the ball port and the pressure relief hole direction See Figure 3 Inspect the valve interior t...

Page 4: ...ection and section 7 to 13 of the ASSEMBLY section 7 OPERATION 7 1 Flush the valves and pipeline with nitrogen whilst preventing the introduction of air moisture or water into the cryogenic valves and...

Page 5: ...rom the pipeline to insure pressure has also been discharged from the valve cavity 8 2 2 Bring the valve handle to the open position 8 2 3 Remove all body bolts 8 2 4 Cryogenic valve end connectors ar...

Page 6: ...2 1 2 with stem 1 1 2 8 2 19 Loosen the 4 cap screws and remove the extended bonnet from the valve body 8 2 20 Support the ball to prevent it from falling out of body Set the ball aside in a clean sec...

Page 7: ...olts to the torque figures table2 and according to tightening pattern illustrated in figure 6 8 3 32 Leave the valve in the open position for flushing the line Reduced bore Full Bore Bolt Thread Tight...

Page 8: ...g tag A167 304 1 Repair kit components Only with HermetiX fire safe design Item Description Material specifications Qty 1 Body A351 CF8M A494 M35 1 Bronze RG5 1 2 End A351 CF8M A494 M35 1 Bronze RG5 2...

Page 9: ...N 127 A2 4 30 Dog tag A167 304 1 Repair kit components Only with HermetiX fire safe design Item Description Material specifications Qty 1 Body A351 CF8M A494 M35 1 Bronze RG5 1 2 End A351 CF8M A494 M3...