habitat et jardin Clean plus Quick Start Manual Download Page 5

EN

The pump

Note:

1.  Pump components are fastened by rotating the pump 

lid between the upper and lower slits of the cartridge

2. 

threads

3. 

4.  The standing components and the cartridge are con-

nected with bolts.

Caution

1.  Do not use the pump when there is no water in the pool

2. 

cables and the plug are in perfect condition.

3.  Voltage and frequency must comply with those stated.

4.  The transformer must be kept at a distance of at least 3,5 

meter from the pool.

5.  The transformer, cable and plug must be kept dry.

6. 

make  sure  that  the  transformer  has  been  disconnected 

from the electricity supply.

7.  If  the  power  cable  is  damaged,  the  pump  must  not  be 

used.

8.  This device is not for intended for use by persons (inclu-

ding children) with limited physical, sensory or mental abi-

lities or those with lack of experience and/or lack of know-

ledge, unless they have been given the task by a person 

responsible  for  their  safetyor  have  received  instructions 

on how to use the device.

9.  Children should be superviced to ensure that they do not 

play with the device.

10.  If the connecting cable on this deviceis damaged, it must 

be replaced by the manufacturer of his After Sales Service 

11.  Do not lift or move the pump by pulling on the power cable.

Part description 

1.  Casing

2.  Filter Cartridge

3. 

4.  Floating ring

5.  Transformer

6.  Bracket

7.  Pump unit

The bracket and clamp 

drive screw and the 

hexagon nut.

1

2

3

5

6

7

4

 Never let the pump turn dry;  

his leads to damage !

1. 

2.  In order to avoid the pump sucking air, submerge the 

pump at least 15 cm below water level.

3.  The water temperature must not be above 35° C

4.  During winter avoid the pump becoming frozen

5.  The pump switches on immediately after plugging the 

transformer into the socket .

Cleaning and servicing

1. 

2.  Remove the pump by twisting the pump unit

3.  Clean the parts

Winter

1.  Unplug the pump from the power source.

2. 

frost and severely cold temperatures. In a garage or 

insulated storage shed is recommended.

fault using the following table, please 

  

♦ switch the device o

ff 

♦ unplug it

Problem

Cause

Possible remedy

Motor does not run

No electricity

Check electricity source, 

switch and wiring (have 

them repaired or replaced by 

professionals)

Impeller is blocked

Dismantle pump and clean it

Windings burnt out

Replace pump

Motor runs but little or no 

water is drawn in

Pump is not fully submerged 

in water

Raise water level or lower 

pump

Impeller damaged
Filter insert clogged 
Rotor turns in the wrong 

direction

Switch transformer off and 

then back on again

Motor runs intermittently Impeller is blockedor is 

permanently overloaded

Clean cartridge and protect 

transformer against over-

heating

Summary of Contents for Clean plus

Page 1: ...Clean plus 1298_89173 ...

Page 2: ...10 SK11 SK12 SK13 SK14 92 55 102mm 1 1 1 φ156 5 248mm 1 1 1 φ109 195mm 1 1 1 φ154 30mm 1 1 1 φ161 5 90mm 1 1 1 φ147 30mm 1 1 2 32 2 65mm 1 1 1 78 54 6 67 5mm 11 4 5mm 1 1 1 88 47 80mm 1 1 1 88 41 375 5mm 1 1 2 M6 35mm 1 1 1 223 5 28mm 1 1 1 φ25 53mm 1298_89173 ...

Page 3: ......

Page 4: ...mum depth below water 0 5 m Please take note of the voltage rating Environmentally friendly disposal Electrical appliances may no longer be disposed of with normal household waste and must be disposed of separately Disposal at communal collection points by private individuals is free of charge Owners of old appliances are required to bring these appliances to the collection points or to make ar ra...

Page 5: ...n the power cable Part description 1 Casing 2 Filter Cartridge 3 4 Floating ring 5 Transformer 6 Bracket 7 Pump unit The bracket and clamp drive screw and the hexagon nut 1 2 3 5 6 7 4 Never let the pump turn dry his leads to damage 1 2 In order to avoid the pump sucking air submerge the pump at least 15 cm below water level 3 The water temperature must not be above 35 C 4 During winter avoid the ...

Page 6: ...ature maximale de l eau 35 C Profondeur maximale en dessous de l eau 0 5 m Veuillez observer la tension indiquée Elimination non polluante Tous les appareils électriques doivent désormais être traités séparément au lieu d être éliminés avec les déchets résiduels Les particuliers peuvent les remettre gratuitement auprès de points de collecte communaux Les détenteurs d appareils anciens sont tenus d...

Page 7: ...ansformateur 6 Ferrure 7 Unité de la pompe La ferrure et la pince doivent être fixées en toute sécourité à l aide de la vis plate cruci forme et de l écrou de serrage hexagonal 1 2 3 5 6 7 4 Première utilisation Ne faites jamais tourner la pompe au sec cela peut l endommager 1 Immergez la pompe du filtre complètement dans l eau et assurez vous que la pompe est remplie d eau 2 Afin d éviter que la ...

Reviews: