Intel Cedar Trail Powered Mini-ITX Motherboard 

 

Chapter 2 Installation Instructions 

2.1 Interfaces Location & Dimension 

Following picture illustrates the interfaces location and dimension of board HB131. Please take   

care of some components during the installation. Improper installation may leads to system   

failure.   

Note: 

In case of any electrostatic damage caused to some components, please wear anti-static 

gloves to install the motherboard.   

 

 

HABEY HB131 Interfaces Location & Dimension 

 

2.2 Installation Steps 

Please refer to following steps to assemble your computer:   

1

Adjust all Jumpers on board HABEY HB131 according to the user manual. 

2

Install Memory 

3

Install other expansion cards 

Summary of Contents for HB131

Page 1: ...HABEY HB131 Mini ITX Motherboard User Manual V1 0 ...

Page 2: ...tronic shock hazard or any damage to the product please ensure that all power cables for the devices are unplugged when adding or removing devices or reconfiguring the system 7 To prevent electrical shock hazard disconnect the power cable from the electrical outlet before relocating the system 8 When adding or removing devices to or from the system ensure that all the power cables for the devices ...

Page 3: ...s Description 8 2 5 1 SATA Ports SATA1 SATA2 PWR_OUT 8 2 5 2 Serial Ports COM1 COM2 COM6 10 2 5 3 Display Interfaces VGA LVDS JVGA 11 2 5 4 LVDS Backlight Control Interface J5 J8 13 2 5 5 LAN_USB Port USB_LAN1 USB_LAN2 USB56 USB78 14 2 5 6 Keyboard and Mouse Interface KBMS 15 2 5 7 GPIO JGP 16 2 5 8 Power Interface ATX 17 2 5 9 FAN Interface CPU_FAN 18 2 5 10 JLPC Interface JLPC 19 2 5 11 Audio JA...

Page 4: ...Configuration 31 3 2 6 Supper IO Configuration 33 3 2 7 H W Monitor 35 3 2 8 Serial Port Console Redirection 36 3 3 Chipset Menu 36 3 3 1 North Bridge 37 3 3 2 South Bridge 38 3 4 Boot Menu 39 3 5 Security Menu 40 3 6 Save Exit Menu 41 Appendix 42 Appendix 1 Watchdog Programming Guide 42 Appendix 2 IRQ System Memory Map 1 st MB Memory Map 43 Appendix 3 Glossary 45 Appendix 4 Install Driver 48 ...

Page 5: ...Chapter 1 Product Introduction ...

Page 6: ... Chipset Intel NM10 Display GPU VGA LVDS VGA 1x standard DB15 VGA resolution up to 1920 1200 60Hz LVDS 1x standard single channel 18 24bit LVDS D2000 series support LVDS resolution up to 1440 900 60Hz Memory 1x single channel SO DIMM slot supports DDRⅢ 800 1066 memory up to 4GB Storage 2x standard 7 Pin SATA ports LAN 2x standard RJ45 LAN ports Transfer rate 10 100 1000Mbps USB Provide 8x USB 2 0 ...

Page 7: ... W83627DHG P I O Chip 6x serial ports 1x DB9 serial ports and five 2 5PIN Header COM1_COM6 support RS232 COM2 also supports RS485 COM2 COM6 provide 5V 12V power supply 1x LPC expansion interface Power Supply Standard ATX 20Pin Watchdog Trigger system reset BIOS 2MB SPI BIOS Environment Operating Temperature 0 60 Storage Temperature 40 85 Operating Humidity 5 95 non condensing ...

Page 8: ...Chapter 2 Installation Instructions ...

Page 9: ...ents during the installation Improper installation may leads to system failure Note In case of any electrostatic damage caused to some components please wear anti static gloves to install the motherboard HABEY HB131 Interfaces Location Dimension 2 2 Installation Steps Please refer to following steps to assemble your computer 1 Adjust all Jumpers on board HABEY HB131 according to the user manual 2 ...

Page 10: ...ints when installing the memory bank 1 Align the notch of the DIMM memory bank with that of the socket Insert the memory bank into the socket and press the memory bank vertically and evenly on both sides until the memory bank enters into the slot 2 Select the memory bank that matches your motherboard 2 4 Jumper Settings Please refer to following instructions to do jumper settings before installing...

Page 11: ...art the computer then press Del to enter BIOS setting and reload optimal defaults 4 Save and Exit JCC Setting JCC 1 2 Clear CMOS BIOS back to factory default 2 3 Normal status system default Do not clear CMOS when the computer is power on otherwise it will cause damage to the motherboard ...

Page 12: ... 2 4 2 Hardware Switch for System Auto Boot upon Power ON JAT JAT Setting JAT Open Disable auto boot Close Enable Auto Boot 2 4 3 COM2 Jumper Setting J1 J2 J1 J2 jumpers are used to configure COM2 transmission mode COM2 supports RS232 RS485 System defaults RS232 ...

Page 13: ...dar Trail Powered Mini ITX Motherboard 7 2 4 4 LVDS Rated Voltage Select Jumper J8 Please first check the LVDS rated work voltage before using it COM2 RS232 default COM2 RS485 J1 1 3 2 4 J1 3 5 4 6 J2 1 2 J2 3 4 5 6 J1 J2 ...

Page 14: ...5 Interfaces Description Please read this manual carefully before installing any external connectors in case of any damage to the motherboard 2 5 1 SATA Ports SATA1 SATA2 PWR_OUT Board provides 2x standard 7 Pin SATA ports One 5Pin SATA_PWR interface PWR_OUT to provide power supply to SATA HDD ...

Page 15: ...HABEY HB131 Intel Cedar Trail Powered Mini ITX Motherboard 9 SATA Pin Signal Name 1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND PWR_OUT Pin Signal Name 1 12V 2 GND 3 VCC 4 GND ...

Page 16: ...D then SATA2 port will be disabled System defaults SATA2 port is enabled MINIPCIE SSD disabled 2 5 2 Serial Ports COM1 COM2 COM6 Board provides 6x serial ports 1x standard DB9 serial port 5x 2 5PIN Header COM1_COM6 support RS232 COM2 also supports RS485 COM1 Pin Signal Name 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS COM1 COM2 COM6 ...

Page 17: ...C 3 RXD DATA 4 RTS NC 5 TXD NC 6 CTS NC 7 DTR NC 8 RI NC 9 GND GND 10 PIN10 PIN10 Note PIN10 define can select 12V 5V or GND 12V 5V is provided via J9 jumper PIN10 Setting 5V 12V Default J9 1 2 2 3 Open COM Power output through custom cable from PIN1 PIN9 of DB9 or any Pin assigned by customer 2 5 3 Display Interfaces VGA LVDS JVGA One standard DB15 VGA display port One standard single channel 18 ...

Page 18: ...REEN 7 GND 12 SDA 3 BLUE 8 GND 13 HSYNC 4 NC 9 5V 14 VSYNC 5 GND 10 GND 15 SCL LVDS Signal Name Pin Signal Name VDD_PANEL 1 2 VDD_PANEL GND 3 4 GND LVDS_TX0_DN 5 6 LVDS_DDC_DATA LVDS_TX0_DP 7 8 LVDS_DDC_CLK GND 9 10 GND LVDS_TX1_DN 11 12 LVDS_CLK_DN LVDS_TX1_DP 13 14 LVDS_CLK_DP GND 15 16 GND LVDS_TX2_DN 17 18 LVDS_TX3_DN VGA LVDS JVGA ...

Page 19: ...ard 13 LVDS_TX2_DP 19 20 LVDS_TX3_DP JVGA Signal Name Pin Signal Name RED 1 2 GND GREEN 3 4 SDA BLUE 5 6 HSYNC GND 7 8 VSYNC VGA_PIN5 9 10 VGA_SCL_R 2 5 4 LVDS Backlight Control Interface J5 J8 J5 Pin Signal Name 1 12V 2 BKLT_EN 3 GND 4 BKLT_CTRL 5 5V J5 J8 ...

Page 20: ...rate sockets provide 2x standard USB 2 0 ports and 1x standard RJ45 LAN port USB_56 USB_78 are internal USB ports Two 2 5Pin header are able to be converted to 4x standard USB ports There will be one LED lamp on each side of the RJ 45 LAN port The yellow one indicates data transfer status The green one indicates network link status Standard USB Port Pin Signal Name 1 5V 2 USB DATA 3 USB DATA 4 GND...

Page 21: ...ive If MINIPCIE uses USB7 interface then the USB7Pin is disabled System defaults USB78 is enabled but MINIPCIE USB function is disabled LAN_LED Status LILED Green Orange Function ACTLED Yellow Function Green 1000M Flash Data transfer Orange 100M Flash Data transfer OFF 10M Flash Data transfer OFF N A OFF No Data 2 5 6 Keyboard and Mouse Interface KBMS Board provides one standard PS 2 interface and...

Page 22: ...r Trail Powered Mini ITX Motherboard 16 KBMS Signal Name Pin Signal Name VCC5 1 2 MS_CLK GND 3 4 MS_DATA KB_DATA 5 6 GND KB_CLK 7 8 VCC5 2 5 7 GPIO JGP General purpose Input Output Port 8bit GPIO One 2 5Pin header PS 2 KB MS ...

Page 23: ...owered Mini ITX Motherboard 17 GPIO Signal Name Pin Signal Name SGPI06 1 2 VCC SGPI07 3 4 SGPI033 SGPI034 5 6 SGPI038 SGPI033 7 8 SGPI039 GND 9 10 GPIO26 2 5 8 Power Interface ATX Board provides one standard ATX 20Pin Power Interface ...

Page 24: ...Pin Signal Name 3 3V 1 11 3 3V 3 3V 2 12 12V GND 3 13 GND 5V 4 14 PS ON GND 5 15 GND 5V 6 16 GND GND 7 17 GND PW OK 8 18 5V 5V SB 9 19 5V 12V 10 20 5V 2 5 9 FAN Interface CPU_FAN Board provides one CPU_FAN interface Keep the following two points in mind when using this interface ...

Page 25: ...ower cable red is in the middle GND black FAN speed pulse signal line other color Recommend to use Fans with speed detection function CPU_FAN Pin Signal Name 1 GND 2 12V 3 Speed detect 2 5 10 JLPC Interface JLPC Board provides one 2 10Pin JLPC Low Pin Count Interface Specification interface to connect external devices or to be used as TPM interface ...

Page 26: ...M LPC_RST 5 6 VCC LPC_AD3 7 8 LPC_AD2 VCC3 9 10 LPC_AD1 LPC_AD0 11 12 GND SMB_CLK 13 14 SMB_DATA 3 3VSB 15 16 SIO_SERIRQ GND 17 18 NC 预留 A20GATE PM_SUS_STAT 19 20 LDRQ_1 2 5 11 Audio JACK_HDA FP_AUDIO Board provides one set Audio interface The green one is Line out The red one is Mic in In built front audio pins Reserve 1x Line in Pin ...

Page 27: ... Powered Mini ITX Motherboard 21 FP_AUDIO Signal Name Pin Signal Name MIC2 L 1 2 AGND MIC2 R 3 4 LINE1 L LINE2 R 5 6 LINE1 R AGND 7 8 NC LINE2 L 9 10 AGND 2 5 12 Parallel Port LPT Board provides one standard parallel port FP_AUDIO ...

Page 28: ...PT_PDQ0 3 4 LPT_ERR LPT_PDQ1 5 6 LPT_INIT LPT_PDQ2 7 8 LPT_SLIN LPT_PDQ3 9 10 GND LPT_PDQ4 11 12 GND LPT_PDQ5 13 14 GND LPT_PDQ6 15 16 LPT_BUSY LPT_PDQ7 17 18 LPT_PE LPT_ACK 19 20 LPT_SLCT 2 5 13 Front Panel Connector JFP One 2 5Pin Front panel header to connect the function buttons and LED lamps on the front panel ...

Page 29: ...Signal Name POWER LED 1 2 POWER LED HD LED 3 4 HD LED VCC 5 6 BUZZDATA RESET BUTTON 7 8 GND POWER BUTTON 9 10 GND Please follow the table below to connect pay attention to the anode and cathode otherwise some function can not be realized POWER LED HDD LED BUZZ RESET BUTTON PWR BUTTON ...

Page 30: ...tem continue to work and no need to turn on off the power 5 Power ON OFF Pins Pin 9 Pin10 for POWER BUTTON Connect these two pins to the bounce switch on the chassis to connect or disconnect the power supply 2 5 14 SO DIMM Slot Onboard one single channel SO DIMM slot supports DDRⅢ 800 1066 MHz RAM up to 4GB 2 5 15 Expansion Interface PCI MINI_PCIE Board provides one standard PCI slot and one MINI ...

Page 31: ...Chapter 3 BIOS SETUP ...

Page 32: ...cuted when it is necessary 2 Please use the BIOS SETUP programs in the CD ROM provided by us or download the latest version on related websites 3 Please do not power off or reboot the system during BIOS upgrading otherwise the BIOS maybe be damaged or system may not be able to boot again 4 After finishing BIOS flash users need to manually select to enter BIOS SETUP LOAD DEFAULT to optimize 5 To pr...

Page 33: ...tem As our company is always ceaselessly update the BIOS SETUP Utility so following BIOS SETUP screens are only for your reference Some may be different from the BIOS you are using now 3 1 Main Menu Aptio Setup Utility Copyright C 2011 American Megatrends Inc Set the Date Use Tab to switch between Date elements BIOS Information BIOS Vendor American Megatrends BIOS Version H131T105 Build Date and T...

Page 34: ...ration Super IO Configuration H W Monitor Serial Port Console Redirection Select Screen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Launch LAN1 2 PXE OpROM Enabled or disabled Boot Option for Legacy Network Devices 3 2 1 ACPI Settings Aptio Setup Utility Copyright C 2011 American Megatre...

Page 35: ...figuration Aptio Setup Utility Copyright C 2011 American Megatrends Inc Enable or disable System wake on alarm event When enabled System will wake on the hr min sec specified RTC Power On Function Enabled RTC Power On Hour 0 RTC Power On Minute 0 RTC Power On Second 0 Select Screen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Co...

Page 36: ...code Revision 268 L1 Cache RAM 2 56 K L2 Cache RAM 2 512 K Processor Core Dual Hyper Threading Supported Hyper Threading Enabled Execute Disabled Bit Enabled Limit CPUID Maximum Disabled EIST Disabled CPU C state Report Disabled Select Screen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc T...

Page 37: ... can result in decreased average power consumption and decreased average heat production CPU C state Report To enable or disable the CPU C state report function C States is the CPU C states power saving modes They are numbered starting at C0 which is the normal CPU operating mode i e the CPU is 100 turned on The higher the C number is deeper is the CPU sleep mode 3 2 4 SATA Configuration Aptio Set...

Page 38: ... traditional IDE Serial ATA Port1 2 To enable or disable the two ports SATA CF under AHCI mode 3 2 5 USB Configuration Aptio Setup Utility Copyright C 2011 American Megatrends Inc USB Configuration USB Devices 1 Drive 1 Keyboard Legacy USB Support Enabled Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available on...

Page 39: ... Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc USB function Disable or enable USB port USB 2 0 EHCI Support Enabled Enable USB EHCI transfer rate up to 480Mpbs Disabled Disable USB2 0 port transfer rate up to 12Mpbs Legacy USB Support Legacy USB supports setting To support USB devices in DOS mode...

Page 40: ...een Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Aptio Setup Utility Copyright C 2011 American Megatrends Inc Enable or Disable Parallel Port LPT LPTE Parallel Port Configuration Parallel Port Enabled Device Settings IO 378h IRQ 5 Change settings IO 378h IRQ 5 Device Mode STD Printer Mode...

Page 41: ...erial Port 1 Configuration Serial Port Enable or disable the serial port function Device Setting Read Only Display the serial port IRQ and Base Address Aptio Setup Utility Copyright C 2011 American Megatrends Inc Enable or Disable Serial Port COM Serial Port 1 Configuration Serial Port Enabled Device Settings IO 3F8h IRQ 4 Change settings IO 3F8h IRQ 4 Select Screen Select Item Enter Select Change...

Page 42: ... Setup Utility Copyright C 2011 American Megatrends Inc PC Health Status SYSTIN temperature 45 CPUTIN temperature 43 CPUVCore 1 216V 3 3VIN 3 379V 5VIN 5 196V Select Screen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc PC Health Status PC health detection BIOS will display the status of th...

Page 43: ...bled Console Redirection Settings Select Screen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Console Redirection Enable or disable Console Redirection Function 3 3 Chipset Menu Aptio Setup Utility Copyright C 2011 American Megatrends Inc North Bridge Parameters North Bridge South Bridge S...

Page 44: ...l Backlight 255 Select Screen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Boot Display Device Select the video Device which will be activated during POST This has no effect if external graphics present Default value is VBIOS Default BIOS Auto detects the connected devices Active LFP Acti...

Page 45: ...elp F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Audio Controller Enable or disable the onboard audio controller LAN 1 2 Controller Enable or disable the onboard LAN1 2 Controller Restore AC Power Loss Select the computer starting up status after restoring the AC power Power Off Press the power button to restart the computer when restore t...

Page 46: ...F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Setup Prompt Timeout Number of seconds to wait for setup activation key 65535 0 FFFF means indefinite waiting If not press setup activation key within the preset time slot system will continue starting up Bootup Numlock State This function allows users to activate Numlock function when boot up ON Numlock is activated...

Page 47: ...gatrends Inc Set Administrator Password Password Description The password length must be in the following range Minimum length 1 Maximum length 20 Administrator Password User Password Select Screen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Administrator Password Set administrator passw...

Page 48: ...creen Select Item Enter Select Change Opt F1 General Help F9 Optimized Defaults F10 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Megatrends Inc Load Defaults Restore Load Default values for all the BIOS setup options Save Change and Exit Press Enter to select this option and press Enter to confirm to save all BIOS changes and exit Discard Change and Exit Press Enter to select thi...

Page 49: ...Appendix ...

Page 50: ... 0x2f unsigned char temp outportb indexp 0x87 outportb indexp 0x87 unlock outportb indexp 0x2d temp unsigned char inportb datap temp 0xfe outportb indexp 0x2d outportb datap temp set pin for watchdog outportb indexp 0x07 outportb datap 0x08 outportb indexp 0x30 outportb datap 0x01 enable logical device outportb indexp 0xf5 outportb datap 0x00 set second outportb datap 0x08 set minute outportb inde...

Page 51: ...umeric data processor 10 14 Available 11 15 Available 12 03 Communication Port COM2 13 04 Communication Port COM1 14 05 Available 15 06 Available 16 07 Intel R N10 ICH7 Family SMBus Controller 27DA System Memory Map Addr range Device 00000000 00003FFF Motherboard resources 000A0000 0000BFFF Intel R Corporation Atom N2000 D2000 Series Embedded Media and Graphics Driver 000C0000 000DFFFF PCI bus 000...

Page 52: ... High Definition Audio DFF04000 DFF043FF Intel R N10 ICH7 Family Serial ATA Storage Controller 27C0 DFF05000 DFF053FF Intel R N10 ICH7 Family USB2 Enhanced Host Controller 27CC E0000000 EFFFFFFF System board FEC00000 FEC00FFF Motherboard resources FED00000 FED003FF High precision event timer FED14000 FED19FFF System board FED1C000 FED1FFFF Motherboard resources FED1C000 FED1FFFF Motherboard resour...

Page 53: ...dware lines BUS here refers to part lines inside CPU and the main components of system memory Chipset Chipset is a Integrated set of chips for executing one or more related functions Here it refers to a system level chipset structured by Southbridge Northbridge It decides the structure and main functions of motherboard CMOS Complementary Metal Oxide Semiconductor which is a widely used semiconduct...

Page 54: ...area generally in a company or a building Local area network is buildup by sever workstation some communications links Terminals can access data and devices anywhere through cables which enables users to share costly devices and resource LED Light Emitting Diode A semiconductor device that shines when power supply is connected It is often used to denote information directly for example to denote p...

Page 55: ...lso can connect other devices like modem USB It is the Universal Serial Bus for short A hardware interface adapts to low speed peripherals and is always used to connect keyboard mouse etc One PC can connect maximum 127 USB devices providing 12Mbit s transmit bandwidth USB supports hot swap and multi data stream namely you can plug USB devices while system is running system can auto detect and make...

Page 56: ...hich you can check from Device Manager 2 Right click my computer select management and go to Device Manager 3 Right click display controller in the menu of graphic card select Properties click Driver select update driver 4 Select Show the list of all drivers which are designated locations so that choices can be made from it select next 5 Select the location of display driver click ok 6 Complete th...