1. Technical data
Pallazza III 520.08
RLU–PGI
Heat output range:
2,4 – 8,3 kW
Nominal heat output:
8,0 kW
Height:
1002 mm
Width:
557 mm
Depth:
493 mm
Weight:
115 kg
Diameter of flue elbow:
80 mm
Flue gas temperature:
206 °C
Testing transport pressure at nominal output:
11 Pa
Testing transport pressure at partial output:
5 Pa
Flue gas flow rate in g/s
5,6 g/s
CO level in flue gas (%) (min./max.)
0,001/0,023 %
Efficiency:
90/95 %
CO level in flue gas:
15 mg/Nm³
NOx level in flue gas:
143/- mg/Nm³
OGC level in flue gas:
<5 mg/Nm³
Proportion of dust in flue gas:
9/- mg/Nm³
Contents of storage container (pellet tank):
about 17 kg
Duration of burn with one charge (min./max.):
about 10 h/30 h
Permitted fuel: Low-dust wood pellets
Diameter: 6 mm
to Ö-Norm M 7135, DIN plus, EN plus-A1
Length: max. 30 mm
Room heating capacity to Ö-Norm M 7521:
max. 230 m³
Room heating capacity to DIN 18893, constant heating:
250m³/145m³/98m³
Room heating capacity to DIN 18893, timed heating:
165m³/95m³/65m³
Electricity supply:
230 V (50 Hz)
Electricity supply input:
in normal operation:
max. 50 W
Electric ignition (for max. 15 minutes on ignition):
max. 380 W
Electronics fuses: (F3)
T 0,315 A, 250 V
Fuses for the ignition, screw conveyor motor, induced draught,
(F1)
T 3,12 A, 250 V
Safety distances
Minimal distances from flammable materials:
side:
15 cm
rear:
10 cm
front (radiation area):
80 cm