GB
1
1. Technical data
HSP 4.0–F3 459.08
Nominal
output
Partial output
50%
Partial output
30%
Heat output range:
8,5 kW
4,0 kW
2,4 kW
Nominal heat output:
8,5 kW
Test conditions defined by norm:
EN 14785
Height:
1210 mm
Width:
540 mm
Depth:
557 mm
Weight:
175 kg
Diameter of flue elbow:
80 mm
Flue gas temperature:
167 °C
100 °C
74 °C
Testing transport pressure:
12 Pa
7 Pa
6 Pa
Flue gas flow rate in g/s:
5,6 g/s
3,8 g/s
2,7 g/s
CO level in flue gas (%) (min./max.)
0,002 %
0,009 %
0,024 %
Efficiency:
91,9 %
94,2 %
95,3 %
CO level in flue gas:
24 mg/Nm³
116 mg/Nm³
295 mg/Nm³
NOx level in flue gas:
65 mg/Nm³
72 mg/Nm³
68 mg/Nm³
OGC level in flue gas:
3 mg/Nm³
2 mg/Nm³
11 mg/Nm³
Proportion of dust in flue gas:
9 mg/Nm³
10 mg/Nm³
18 mg/Nm³
Contents of storage container (pellet tank):
ca. 17 kg
Duration of burn with one charge (min./max.):
ca. 9 h
ca. 18 h
ca. 18 h
Permitted fuel: Low-dust wood pellets
diameter: 6 mm
to Ö-Norm M 7135, DIN plus, EN plus-A1
length: max. 30 mm
Room heating capacity to Ö-Norm M 7521:
max. 230 m³
Electricity supply:
230 V (50 Hz)
Electricity supply input:
in normal operation:
21 W
Electric ignition (for max. 15 minutes on ignition):
max. 380 W
Fuses for the ignition, screw conveyor motor, induced
draught, (F1)
T 3,15 A, 250 V
Safety distances
Minimal distances from flammable materials:
side:
10 cm
rear:
10 cm
front (radiation area):
50 cm
Summary of Contents for HSP 4.0-F3
Page 1: ...HSP 4 0 F3 Equipment sheet Pellet stove GB 0545908001403e Equipment sheet HSP 4 0 F3...
Page 4: ......
Page 11: ...Cleaning work GB 7 Figure 1 Cleaning the combustion pot using the supplied tool...
Page 14: ...Maintenance work GB 10 Figure 3 Removing the side wall...
Page 22: ...Circuit diagram GB 18 6 Circuit diagram 6 1 Circuit diagram IO 57 1...