Please read this Operation Manual carefully. It will provide you information of the function and operation of this stove, 
and in addition, proper heating will allow you saving fuel and behaving environment-friendly.  
The enclosed  

specification

 forms a part of this Operation Manual. 

1. General instructions

When unpacking the appliance, please check whether it has not suffered harm during transport. 
Report possible faults to your specialised vendor of stoves immediately!
Note: The return draft boards which are loose or which loosened from their embedding etc. do not 
constitute defects (see Specification 

–First putting into service).

During the installation, connection and putting in operation there must be observed national and 
European standards, local and building regulations, as well as the Building Order of the respective 
country, or the Decree of fire-boxes.

The fireplace stove, described in this Manual, has been checked according to DIN EN13240. The 
door of the combusting space must be closed during the heating always. 

The fireplace stove is a fire box for interrupted combustion, and is suitable for multiple employment 
of a chimney.
Please observe the international regulations.

2. Safety instructions

If the combustion air is taken from the living room, a sufficient input of fresh air must be secured in 
any case.

The appliances for suction of air, such as ventilation appliances, fume hoods, laundry driers with
discharge of waste air etc., or other fire boxes must not exert a negative impact on the supply of air
to the stove.

With the stoves equipped with an intake of external air, the orifice must not be closed during 
operation of the stove.

During operation of the stove, the installed orifice for the intake of combustion air must not be 
closed, partially closed, straitened, covered or blocked.

During the operation, the fireplace stove warms up intensely. Therefore, the stove is attended 
employing a protecting glove which is included in the scope of the delivery.

Alert children to this danger, and take care that they may not linger in the vicinity of the stove when 
it is in operation.

The fireplace stove must not be brought into operation  at the same time with the controlled ventilation 

appliances in the flat. 

2.1.  Proper conduct in case of a fire in the chimney. 

If employing improper or wet fuel, a fire can be produced in the chimney due to the accretions in the
chimney.

Proper conduct 

Shut all the air orifices of the stove immediately.

Inform the fire brigade and the chimneysweep.

Provide access to cleaning orifices.

Once the fire is over, have the chimney inspected by an expert in fissures and leaks.

Ascertain the reason of the fire in the chimney.

3. Chimney

3.1.  Weather conditions

For safe operation of the fire box, it is always necessary to secure that the chimney may have a sufficient draft. In 
particular, this issue must be taken in consideration in transition seasons (e.g. in the spring, in the autumn etc.). 

Summary of Contents for DK LAUSITZ easy

Page 1: ...ois avec EASY CONTROL FR Istruzioni per il posizionamento e l uso Stufa camino con EASY CONTROL IT Instructions for emplacement and operation Fireplace stove with EASY CONTROL GB Upute za namje tanje...

Page 2: ...n parts 4 4 2 Inlet of combustion air 5 4 3 Input connection of external air provided it is installed 5 5 Operation of the fireplace stove 5 5 1 Suitable fuels 5 5 2 Unsuitable fuels 5 5 3 First putti...

Page 3: ...entilation appliances fume hoods laundry driers with discharge of waste air etc or other fire boxes must not exert a negative impact on the supply of air to the stove With the stoves equipped with an...

Page 4: ...mney Al the orifices mouthed into the same chimney such as cleaning orifices of the stove and of the chimney must be shut In case of multiple employment of the chimney the minimum vertical distance of...

Page 5: ...ffer damage by the consequence of which any guarantee ceases to exist 5 3 First putting in operation Prior to first putting in operation it is necessary To remove stickers if there are any To take out...

Page 6: ...ns of a poker and to empty the ash pan Please mind to empty the ash pan meanwhile it is approximately half full so that the layer of ashes may not touch the grate There is a danger that the circulatio...

Page 7: ...not tight sealing of the door of the glass Replace the sealing The draft of the chimney too big min 20 Pa in the neck of combustion products Have a draft limiter installed The glass of the door gets s...

Page 8: ...n vendor from whom you have bought the appliance 8 Guarantee HAAS SOHN gives the buyer a guarantee in the frame of valid legal regulations The two year guarantee runs from the moment of the actual han...

Reviews: