2. Technical data
Pelletto III 419.08
Pelletto III 434.08
Heat output range:
2,4 – 8,3 kW
2,4 – 8,3 kW
Nominal heat output
8,0 kW
8,0 kW
Height:
1001 mm
1193 mm
Width:
557 mm
557 mm
Depth:
493 mm
493 mm
Weight:
96/143/115 kg
106/137 kg
Diameter of flue elbow:
80 mm
80 mm
Flue gas temperature
172°C
172°C
Minimum supply pressure:
11 Pa
11 Pa
Flue gas flow rate in g/s
5,6 g/s
5,6 g/s
CO
level in flue gas (%) (min./max.)
0,0012/0,01 %
0,0012/0,01 %
Efficiency:
90/97,2%
90/97,2%
CO level in flue gas:
15 mg/Nm³
15 mg/Nm³
NO
x
level in flue gas:
143/- mg/Nm³
143/- mg/Nm³
OGC level in flue gas:
<5 mg/Nm³
<5 mg/Nm³
Proportion of dust in flue gas:
9/- mg/Nm³
9/- mg/Nm³
Contents of storage container (pellet tank):
about 17 kg
about 32 kg
Duration of burn with one charge (min./max.):
about 10 hrs / 30 hrs
about 20 hrs / 60 hrs
Permitted fuel: Low-dust wood pellets to Ö-Norm (Eco-
standard) M 7135, DIN 51731, EN 14961-2
Diameter: 6 mm,
Length: max. 30 mm
Diameter: 6 mm,
Length: max. 30 mm
Room heating capacity to Ö-Norm M 7521:
max. 230 m
3
max. 230 m
3
Room heating cap’y to DIN 18893, constant heating:
250m
3
/145m
3
/98m
3
250m
3
/145m
3
/98m
3
Room heating cap’y to DIN 18893, timed heating:
165m
3
/95m
3
/65m
3
165m
3
/95m
3
/65m
3
Electricity supply:
230 V (50 Hz)
230 V (50 Hz)
Electricity supply input (min./max.)
in normal operation:
Electric ignition (for max. 15 minutes on ignition):
30 to 50 W
400 W
30 to 50 W
400 W
Electronics fuses: (F3)
T 0.315 A, 250 V
T 0.315 A, 250 V
Fuses for the ignition, screw conveyor motor, induced
draught, (F1)
T 3,15 A, 250 V
T 3,15 A, 250 V
Summary of Contents for Pelletto III 419.08
Page 8: ...8 Figure 6 Dimensions of Pelletto III 419 08 Pelletto III 419 08 C ...
Page 9: ...9 Figure 7 Dimensions of Pelletto III 434 08 Pelletto III 434 08 C ...
Page 10: ...10 Figures 8 Replacement parts Pelletto III 419 08 Pelletto III 419 08 C ...
Page 11: ...11 Figures 9 Replacement parts Pelletto III 434 08 Pelletto III 434 08 C ...
Page 13: ...13 4 Circuit diagram ...