2-17
•
Make sure AP installation is complete and the AP is installed correctly before powering on the
AP.
CAUTION:
To prevent device damage, attach weatherproof caps tightly to connectors that are not in use.
NOTE:
When you apply weatherproof tape to the power cord, follow these restrictions and guidelines:
•
Make sure you attach the adhesive side of the tape to the cable connector.
•
Pull the tape as needed for overlap.
•
Start wrapping at the top of the connector, and overlap the tape to half-width. Avoid creases or
wrinkles and press the tape against the connection so that there are no gaps. Smooth each
wrapped layer with your hands to ensure full adhesion.
AC liquid-tight adapter
shows a AC liquid-tight adapter.
describes the adapter specifications.
Figure2-32 AP power connector and AC liquid-tight adapter header
Table2-1 Weatherproof AC connector specifications
Item
Specification
Cable diameter
5.5 to 8 mm (0.22 to 0.32 in)
Maximum current
20 A
Maximum voltage
250 V
Power cord wires
16 AWG to 20 AWG
Connecting the AC power cord
1.
Attach the fastening nut to the AC liquid-tight adapter header.
Figure2-33 Assembling the nut and the liquid-tight adapter
2.
Use a Phillips screwdriver to loosen the screws on the header, and then feed the cable through
the sealing nut and sealing washer
AC liquid-tight adapter
L
PE
Description
1
Pin
2
3
2 3
1
N