5
Connecting the AP to the power source and the network
连接电源并将设备接入网络
To use the PoE1 port on the PoE injector as an example to connect the AP:
Connect PoE1 on the injector to GE1 on the AP. Connect LAN1 on the injector to an Ethernet copper port
on the AC. Connect the PoE injector and AC to the power sources.
将
PoE
注入器的
PoE1
口连接到设备的
GE1
接口;将
PoE
注入器的
LAN1
口连接到
AC
的以太网电口;将
PoE
注入器和
AC
连接到交流电源。
Before connecting the AP to the power source, make sure the grounding cable is correctly connected.
The PoE1 port on the PoE injector is uplinked to the AC through the LAN1 port, and PoE2 through
LAN2. For sufficient power, use a PoE injector to supply power to only one AP.
设备连接电源线之前,需要确保接地线已正确接地。
PoE
注入器的
PoE1
接口对应
LAN1
接口,
PoE2
接
口对应
LAN2
接口。一个
PoE
注入器建议只给一台
AP
供电。
!
Connecting an Ethernet cable
连接以太网线缆
Disassemble the liquid-tight adapter and detach the rubber split sealing washer. Feed the Ethernet cable
through the liquid-tight adapter and attach the split sealing washer. Connect the Ethernet cable to the
target port on the AP and fasten the liquid-tight adapter.
拧开防水接头,掰开防水胶塞,将网线穿过防水接头,扣紧防水胶塞。将网线连接到设备的以太网口,然后
拧紧防水接头。
Connecting optical fibers
连接光纤
PoE injector
PoE
注入器
AC
1
2
Connecting the grounding cable
连接保护地线
Correctly connecting the grounding cable is crucial to lightning protection and EMI protection. N o
grounding cable is provided with the AP. Prepare one yourself. Make sure the cross sectional area of
the grounding cable is over 3 mm² (0.0047 in²) and the ring terminal has an inner diameter of more
than 4 mm (0.16 in).
设备地线的正确连接是设备防雷、防干扰的重要保障。设备需要使用截面积大于
3mm²
,端子内径大于
4mm
的保护地线,保护地线不随机提供,请用户根据需要单独购买。
Remove the dust plug from the fiber port and insert a transceiver module into the port. Feed the LC
connectors of the optical fibers through the liquid-tight adapter and insert them into the transceiver module.
Then fasten the liquid-tight adapter.
拆下设备光口的防尘塞,将光模块插入光接口,将
LC
型光纤连接器穿过防水接头,然后插入光模块接口,拧
紧防水接头。
Use the grounding screw to attach the ring terminal of the grounding cable to the grounding point on the
AP. Connect the other end of the grounding cable to a reliable earth ground.
将接地线一端固定到设备的接地螺钉上,另一端连接到大地上。
1
2
3
1
2
GE1
LAN1
PoE1
1
2
Only one liquid-tight adapter is supplied with the device. If more adapters are needed, purchase them yourself.
设备仅随机附带一个防水接头,用户可根据需要单独购买。
Copyright © 2018, New H3C Technologies Co., Ltd.
The information in this document is subject to change without notice.
Copyright © 2018
新华三技术有限公司 版权所有,保留一切权利
本文档中的信息如有更改,恕不另行通知
如需了解产品及安装方面的更多信息,请登录
H3C
网站
www.h3c.com