92
CAUTION:
To avoid poor contact between the processor and the system board or damage to the pins in
the processor socket, tighten the screws to a torque value of 1.4 Nm (12 in-lbs).
Figure 115 Attaching the retaining bracket and heatsink to the processor socket
10.
Install fans. For more information, see "
11.
Install DIMMs. For more information, see "
12.
Install the chassis air baffle. For more information, see "
13.
Install the access panel. For more information, see "
14.
Rack-mount the server. For more information, see "
."
15.
Connect the power cord. For more information, see "
16.
Power on the server. For more information, see "
Verifying the installation
Log in to HDM to verify that the processor is operating correctly. For more information, see HDM
online help.
Installing DIMMs
The server supports DCPMMs and DRAM DIMMs (both LRDIMM and RDIMM supported).
Compared with DRAM DIMMs, DCPMMs provide larger capacity and can protect data from getting
lost in case of unexpected system failures.
Both DCPMMs and DRAM DIMMs are referred to as DIMMs in this document, unless otherwise
stated.
Guidelines
WARNING!
The DIMMs are not hot swappable.
You can install a maximum of 12 DIMMs for each processor, six DIMMs per memory controller. For
more information, see "DIMM slots."