10
Item
Specifications
with SlimSAS port 1.
Form factors of PCIe modules
FHFL
Maximum power supplied per PCIe slot
75 W
Figure 24 RC-3FHFL-2U-SW-G5 riser card
(1) PCIe slot 3/6
(2) PCIe slot 2/5
(3) SlimSAS connector 2
(4) GPU module power connector
(5) SlimSAS connector 1
(6) PCIe slot 1/4
Fan modules
The server supports four hot swappable fan modules. The server supports N+1 fan module
redundancy.
shows the layout of the fan modules in the chassis.
The server can adjust the fan rotation speed based on the server temperature to provide optimal
performance with balanced ventilation and noise.
During system POST and operation, the server will be gracefully powered off through HDM if the
temperature detected by any sensor in the server reaches the critical threshold. The server will be
powered off directly if the temperature of any key components such as processors exceeds the
upper threshold. For more information about the thresholds and detected temperatures, access the
HDM Web interface and see HDM online help.