6-35
Installing a diagnostic panel
Preparing for the installation
Verify that the diagnostic panel is compatible with your server model, as follows:
•
SFF diagnostic panel for 8SFF and 10SFF servers.
•
LFF diagnostic panel for the 4LFF server.
For the installation location of the diagnostic panel, see "Front panel view."
Identify the diagnostic panel cable before you install the diagnostic panel. The P/N of the cable is
0404A0SP.
Procedure
The installation procedure is the same for SFF and LFF diagnostic panels. This procedure uses an
SFF diagnostic panel as an example.
To install a diagnostic panel:
1.
Power off the server. For more information, see "
2.
Remove the security bezel, if any. For more information, see "
3.
Remove the blank or drive from the slot in which the diagnostic panel will be installed.
For more information about removing the blank, see "
."
For more information about removing the drive, see "
4.
Install the diagnostic panel:
a.
Connect the diagnostic panel cable to the diagnostic panel, as shown in
.
Figure 6-51 Connecting the diagnostic panel cable to the diagnostic panel
b.
Push the diagnostic panel into the slot until it snaps into place, as shown in
.
Figure 6-52 Installing the SFF diagnostic panel