6-14
Installing a standard storage controller and a power fail
safeguard module
Procedure
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Install the flash card of the power fail safeguard module to the storage controller:
IMPORTANT:
Skip this step if no power fail safeguard module is required or the storage controller has a
built-in flash card. For information about storage controllers with a built-in flash card, see
"Storage controllers."
a.
Install the two internal threaded studs supplied with the power fail safeguard module on the
storage controller, as shown in
Figure 6-21 Installing the internal threaded studs
b.
Slowly insert the flash card connector into the socket and use screws to secure the flash
card on the storage controller, as shown in