<Sysname>
Accessing the switch module through SOL serial port
redirection
Prerequisites
•
The switch module has been powered on. For information about powering on the switch module,
see "Powering on the module."
•
You have accessed the OM CLI. For information about accessing the OM CLI, see "Accessing
the OM CLI."
Procedure
Execute the
sol connect
command to access the CLI of the target switch module.
The switch module in slot 1 is used in this example.
<OM>sol connect io 1
Begin to edit commands.
<Sysname>%Jul 29 13:42:35:975 2013 H3C SHELL/5/SHELL_LOGIN: Console logged in from c
on1.
<Sysname>
NOTE:
After accessing the switch module CLI through SOL serial port redirection, you can enter "~" and "."
in sequence in any view ("~" will not be displayed on the CLI) and then press
Enter
to return to the
CLI of the OM module.
Configuring a management IP address for the
switch module
Obtaining and planning related data
Obtain and plan related data as described in
before configuring a management IP address
for the switch module.
Table 10 Obtaining and planning related data
Parameter
Setting
Data to obtain
OM management IP
•
Management IP address (default): 192.168.100.100
•
Subnet mask (default): 255.255.255.0
OM username and password
•
Username (default): admin
•
Password (default): Password@_