33
6.
On the screen as shown in
, select the RAID array you want to view and press
Enter
to view detailed information about the RAID array (including RAID array name, level, and drive
information).
Figure 58 Selecting the target RAID array
Configuring hot spare drives
In legacy mode, if a hot spare drive is configured for a RAID array, the hot spare drive will not take
effect on other RAID arrays. To avoid this problem, configure all RAID arrays and then add hot
spare drives.
To configure a hot spare drive:
1.
On the storage controller configuration screen as shown in
, select
Array
Configuration
and press
Enter
.
Figure 59 Storage controller configuration screen
2.
On the screen as shown in
, select
Manage Arrays
and press
Enter
.
Summary of Contents for UniServer B5700 G3
Page 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Page 116: ...56 Figure 96 Controller Configuration screen...
Page 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Page 243: ...84 Figure 153 Confirming the operation...
Page 293: ...50 Figure 89 Clearing completion...
Page 382: ...21 Figure 27 Storage controller information...
Page 389: ...7 Figure 8 Identifying a storage controller 2...