13-156
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the number of
concurrent users
configure-user count number
Optional
Two users are allowed to perform
the operation concurrently in
system view.
z
When multiple users enter system view concurrently to configure certain attribute, only the last
configuration applies.
z
When the number of users has reached the upper limit, other users cannot enter system view.
Configuring the Exception Handling Method
When the system detects any software abnormality, it handles the situation with one of the following two
methods:
z
reboot
: The system recovers itself through automatic reboot.
z
maintain
: The system stays in the current state. Therefore, you need to manually recover the
system, such as reboot the system. Sometimes, it is difficult for the system to recover, or some
prompts that are printed during the failure are lost after the reboot. In this case, you can use this
method to keep the abnormal state and troubleshoot the problem.
Follow these steps to configure the exception handling method (On the SR6602 router):
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the exception handling
method
system-failure
{
maintain
|
reboot
}
Optional
By default, the system adopts the
reboot
method to handle
exceptions.
Follow these steps to configure the exception handling method (On the SR6604/6608/6616 router):
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the exception handling
method on the active main board
(AMB) and the standby main board
(SMB)
system-failure
{
maintain
|
reboot
}
Optional
By default, the AMB and the SMB
adopt the
reboot
method to handle
exceptions.
Summary of Contents for SR6600 SPE-FWM