Figure 1 NSQ1SUPB0 MPU 

 

 

 

Specifications 

Figure 2 Front panel of the NSQ1SUPB0 

 

(1) Console port (CONSOLE) 

(2) 10/100/1000BASE-T copper combo port GE3 

(3) Management Ethernet port LED 

(4) Fan status LED

(5) Card status LED

(6) MPU status LED (ACTIVE) 

(7) Reset button 

 

 

Table 1 Card specifications 

Item Specification

Dimensions (H × W × D) 

40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) 

Power consumption 

45 W to 50 W 

Weight 

2.97 kg (6.55 lb) 

Hot swapping 

Supported 

Connector type 

RJ-45 

Interfaces 

 

1 console port 

 

One 10/100/1000BASE-T Ethernet port 

Ambient temperature 

Operating: 0°C to 45°C (32°F to 113°F) 
Storage: –40°C to +70°C (–40°F to +158°F) 

3

4

5

1

2

6 7

Summary of Contents for SecPath M9000 NSQ1SUPB0 MPU

Page 1: ...Ethernet port LED 4 Fan status LED 5 Card status LED 6 MPU status LED ACTIVE 7 Reset button Table 1 Card specifications Item Specification Dimensions H W D 40 399 352 mm 1 57 15 71 13 86 in Power consumption 45 W to 50 W Weight 2 97 kg 6 55 lb Hot swapping Supported Connector type RJ 45 Interfaces 1 console port One 10 100 1000BASE T Ethernet port Ambient temperature Operating 0 C to 45 C 32 F to ...

Page 2: ...9 21 ft Services Provides connection to an ASCII terminal Provides connection to the serial port of a local or remote through a pair of modems PC running terminal emulation program Supports command line interface CLI Table 3 10 100 1000BASE T copper port specifications Item Specification Connector RJ 45 Interface standard 802 3 802 3u and 802 3ab Interface type MDI MDIX autosensing Supported cable...

Page 3: ...OTE A quick flashing RUN LED indicates that the card is starting up rather than operating properly It is normal that the ALM LED for an LPU lights for a period of time at the initial phase of the system startup Table 7 MPU ACTIVE LED description LED status Description On The MPU is active Off The MPU is in standby status The MPU is faulty Examine the card LED for an MPU problem 4 Installing and re...

Page 4: ...ips screwdriver and installation is finished 4 2 Removing the NSQ1SUPB0 1 Use a Phillips screwdriver to loosen the captive screws at both sides of the card until all pressure is released 2 Pull the ejector levers at both sides of the card outward and pull the card along the guide rails until it completely comes out of the backplane 3 Place the card on an anti static workbench with the surface moun...

Reviews: