12
Figure 7 Removal flow
Before removing the power module, prepare an ESD wrist strap and
a Phillips screwdriver.
Removing the power cord
1.
Turn off the circuit breakers for the power cord.
2.
Wear an ESD wrist strap, and make sure that the wrist strap
makes good skin contact and is reliably grounded.
3.
Loosen the screw that fastens the power cord plug, and pull the
plug out.
Removing the power module
1.
Use the Phillips screwdriver to loosen the captive screw on the
power module.