background image

5

Remove a fan tray

拆卸风扇

Install a fan tray

安装风扇

Installing and removing a fan tray 

风扇模块的安装与拆卸

1

2

2

2

1

1

6

Install a filler panel

安装假面板

Remove a filler panel

拆卸假面板

Connect the DC power cord 

连接直流电源线

Connect the AC power cord 

连接交流电源线

Use a removable cable tie to secure the power cord. The method for securing AC and DC power cords 

are the same. The following figure uses the AC power cord as an example. 

使用可拆卸式扎带固定电源线,以防止电源线脱落;直流电源线和交流电源线的固定方式相同,此处以交
流电源线为例介绍电源线的固定过程。

Connecting the power cord 

电源线的连接

Install a power module

安装电源模块

Remove a power module

拆卸电源模块

2

1

1

2

The LSWM1HFANSC fan tray provides forward airflow from the power module side to the port 

side. The LSWM1HFANSCB fan tray provides reverse airflow from the port side to the power 

module side.  LSWM1HFANSC

为吹风风扇,电源侧进风,端口侧出风;

LSWM1HFANSCB

为抽风

风扇,端口侧进风,电源侧出风。

Before installing a fan tray, make sure the airflow direction marked on the fan tray meets the 

ventilation requirements at the installation site. 

安装风扇模块前,请根据风扇模块的风向指示,确

认气流方向和安装环境的通风要求一致。

The switch comes with the fan tray slots empty. You must install two fan trays of the same model 

for the switch for adequate heat dissipation. Do not power on the switch when no fan tray is 

installed.

交换机出厂时两个风扇插槽均为空,为保证设备的正常散热,用户必须安装两个相同型号

的风扇模块,否则禁止交换机上电运行。

If both fan trays fail when the device is operating, finish replacing the fan trays within 2 minutes.

备运行过程中,如果两个风扇模块均出现故障,则必须在

2

分钟内完成故障风扇模块的更换。

If one fan tray fails when the switch is operating and the ambient temperature is not higher than 

27°C (80.6°F), replace the fan tray within 24 hours, and make sure the faulty fan tray is in position 

before replacing it. If the ambient temperature is higher than 27°C (80.6°F), replace the fan tray 

immediately.

设备运行过程中,如果一个风扇模块出现故障,则当环境温度不高于

27

℃时,必须在

24

小时内完成故障风扇模块的更换,且更换前需保持故障风扇模块在位;当环境温度高于

27

℃时,

请立即进行更换。

Make sure each hot swappable module slot is installed with a module or filler panel when the 

switch is operating. 

设备运行过程中,必须确保所有可插拔模块插槽不能为空,请务必安装相应的

模块或假面板。

!

Before connecting the power cord, connect the grounding cable and make sure the switch is 

reliably grounded.

在连接电源线前,您需要先连接接地线,保证交换机正确接地。

Connect the power cord to the switch first and then to the power source to avoid bodily injury. 

连接电源线时,请先完成电源线与交换机侧的连接,再进行电源线与供电系统的连接,以免造成人
身伤害。

!

Install a filler panel in an empty power module slot to prevent dust from entering the chassis and 

ensure good ventilation.

若电源模块插槽没有安装电源模块,请及时安装假面板,以保证设备的良好通风散热并防止灰尘进入
交换机。