Installing the accessories to the switch

安装附件到交换机

The following installation procedures are for the S5830-52SC. The installation 
procedures for the S5830-106S are similar.

如下安装过程,以安装到

S5830-52SC

交换

机上为示意,

S5830-106S

的安装类似,不再重复描述。

The installation positions of the accessories in the following figure are only for 
illustration. Select proper installation positions based on the installation requirement.

下图中附件的安装位置仅供参考,请根据实际安装场景的需要选择合适的安装位置。

Position a or b near the power modules

靠近电源侧,可以安装在a处或b处

Position c or d near 

the network ports

靠近端口侧,可以

安装在c处或d处

a

b

c

d

6

Grounding cable installation position of the S5830-106S (two options) S5830-106S

Primary grounding point

 (near the power 

modules)

主接地点(靠近电源侧)

Auxiliary grounding

 point (near the network ports)

备用接地点

(靠近端口侧)

The S5830-106S provides a grounding sign at the primary grounding point, but does not 
provide it at the auxiliary grounding point. S5830-106S

主接地点标有接地标识,备用接

地点上无接地标识。

1

2

3

3

 

The primary and auxiliary grounding points of the S5830 Switch Series are located at the 
chassis side. Install the grounding cable before installing the switch to the rack. 
S5830

系列交换机提供的主接地点和备用接地点均位于机箱侧面,为了防止机箱安装到机

柜后无法安装接地线,因此请先将接地线安装到交换机的侧面接地点上。

Installing the switch to a 19-inch rack

安装交换机到

19

英寸机柜

Install cage nuts to the square 

holes of the rack

Install slide rails to the rack

Mount the switch to the rack

Connect the other end of the 

grounding cable to the grounding 

point of the rack

接地线另一端连接到机柜接地点

The S5830-52SC with short slide rails applies to the rack with a front-to-rear post 
distance of 401 mm (15.79 in) to 654 mm (25.75 in).

使用短滑道时,

S5830-52SC

用于前后方孔条间距在

401mm

654mm

之间的机柜。

The S5830-52SC with long slide rails applies to the rack with a front-to-rear post 
distance of 621 mm (24.45 in) to 874 mm (34.41 in).

使用长滑道时,

S5830-52SC

用于前后方孔条间距在

621mm

874mm

之间的机柜。

The S5830-106S applies to the rack with a front-to-rear post distance of 489 mm 
(19.25 in) to 993 mm (39.09 in).S5830-106S

适用于前后方孔条间距在

489mm

993mm

之间的机柜。

Airflow direction of the switch

交换机的风向设计

1

2

3

4

Switch and rack compatibility

对机柜的要求:

 