61
To do…
Use the command…
Remarks
Configure the data
bits
databits
{
5 | 6 | 7
|
8
}
Optional
By default, the data bits of the AUX
port is 8.
Data bits is the number of bits
representing one character. The
setting depends on the contexts to
be transmitted. For example, you
can set it to 7 if standard ASCII
characters are to be sent, and set it
to 8 if extended ASCII characters
are to be sent.
Define a shortcut
key for starting a
session
activation-key
character
Optional
By default, you can press
Enter
to
start a session.
Define a shortcut
key for terminating
tasks
escape-key
{
default
| character }
Optional
By default, you can press
Ctrl+C
to
terminate a task.
Configure the flow
control mode
flow-control
{
hardware
|
none
|
software
}
Optional
By default, the value is
none
.
The switch supports the
none
flow
control mode only.
Configure the type
of terminal display
terminal type
{
ansi | vt100
}
Optional
By default, the terminal display type
is ANSI.
The device supports two types of
terminal display: ANSI and VT100.
H3C recommends you to set the
display type of both the device and
the client to VT100. If the device and
the client use different display types
(for example, hyper terminal or
Telnet terminal) or both are set to
ANSI, when the total number of
characters of the currently edited
command line exceeds 80, an
anomaly such as cursor corruption
or abnormal display of the terminal
display may occur on the client.
Configure the user
privilege level for
login users
user privilege level
level
Optional
3 by default.
Set the maximum
number of lines on
the next screen
screen-length
screen-length
Optional
By default, the next screen displays
24 lines at most.
A value of 0 disables the function.