41
•
Solution
To resolve the problem:
a.
Verify that the switch power cord is correctly connected.
b.
Verify that the power source meets the requirement.
c.
Verify that the operating temperature of the switch is in an acceptable range and the power
module has good ventilation.
d.
If the problem persists, contact H3C Support.
To replace a hot swappable power module, see "
Installing/removing a power module
."
Fan failure
The S5150-EI series switches use fixed fans. If a fan failure occurs, contact H3C Support and do not
attempt to fix the problem yourself.
Configuration terminal display problems
If the configuration environment setup is correct, the configuration terminal displays booting
information when the switch is powered on. If the setup is incorrect, the configuration terminal
displays nothing or garbled text.
No display
Symptom
The PC displays nothing when the switch is powered on.
Solution
To resolve the problem:
1.
Verify that the power module is supplying power to the switch.
2.
Verify that the console cable is correctly connected.
3.
Verify that the console cable does not have any problems and the PC settings are correct.
4.
If the problem persists, contact H3C Support.
Garbled display
Symptom
The display on the PC is garbled.
Solution
To resolve the problem:
1.
Verify that the following settings are configured for the terminal:
{
Baud rate
—9,600.
{
Data bits
—8.
{
Parity
—None.
{
Stop bits
—1.
{
Flow control
—None.
2.
If the problem persists, contact H3C Support.