27 

{

 

Execute the 

display stp brief

 command to verify that STP does not set the state of the port 

to 

discarding

. When the port is in 

discarding

 state, it cannot forward traffic. H3C 

recommends that you disable STP on the port, or configure the port as an edge port if the 
port is connected to a terminal device. 

{

 

If the port belongs to an aggregation group, execute the 

display link-aggregation verbose

 

command to identify the port status. When the port is an Unselected port, it cannot forward 
traffic. Locate the reasons why the port is in Unselected state. For example, the attribute 
configurations of the port are different from the configurations of the reference port. 

{

 

If the port belongs to a smart link group, execute the 

display smart-link group

 command to 

verify the port status. The port cannot forward packets if its state is standby or down. If the 
port is standby, configure the port as a primary port. If the port is down, verify the causes and 
resolve the problem as required. A port might go down if the uplink device is configured with 
the monitor link function, the port is shut down, or the link fails.  

4. 

Examine the following configurations that might cause packet loss: 

{

 

VLAN configuration

—Execute the 

display this

 command in Ethernet interface view to 

verify that the port is in the VLAN of the packets. If it is not, add the port to the VLAN. 

{

 

Blackhole MAC address entries

—Execute the 

display mac-address blackhole

 

command to display blackhole MAC address entries. If the packets are discarded because 
they match a blackhole MAC address entry, delete the entry. To delete the blackhole MAC 
address entry, execute the 

undo mac-address blackhole mac

-

address

 

vlan

 

vlan

-

id

 

command. 

{

 

Rate limit

—Execute the 

display qos lr interface

 command to display the rate limit 

configuration on the port. If rate limit is configured on the port, make sure the committed 
information rate (CIR) and the committed burst size (CBS) are appropriate. To adjust the 
CIR and CBS values, execute the 

qos lr

 { 

inbound

 | 

outbound

 } 

cir

 

committed-information-rate

 [

 cbs

 

committed-burst-size 

] command. 

{

 

Storm suppression

—Execute the 

display this

 command in Ethernet interface view to 

display the configuration of storm suppression. Storm suppression includes broadcast 
suppression, multicast suppression, and unknown unicast suppression. To adjust the 
suppression thresholds, execute the 

broadcast-suppression

multicast-suppression

and 

unicast-suppression

 commands, respectively. 

5. 

Verify that no congestion occurs by using the 

display qos queue interface

 command. 

If congestion occurs, locate and resolve the problem by referencing related congestion 
management documents. 

6. 

If the problem persists, contact H3C Support. 

Related commands 

This section lists the commands that you might use for troubleshooting Layer 2 forwarding failure. 

 

Command  

Description 

display dot1x 

Displays session information, statistics, and configurations 
about 802.1X. 

display interface 

Displays Ethernet interface information. 

display ip source binding 

Displays IPv4 source guard binding entries. 

display ipv6 source binding 

Displays IPv6 source guard binding entries. 

display link-aggregation verbose 

Displays detailed information about the aggregation groups 
that correspond to the aggregate interfaces. 

display mac-address blackhole 

Displays blackhole MAC address entries. 

display mac-forced-forwarding vlan  

Displays MFF information for a VLAN. 

Summary of Contents for S5150-EI Series

Page 1: ...2 Copyright 2017 New H3C Technologies Co Ltd All rights reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologi...

Page 2: ...mptom 7 Solution 7 Related commands 8 Troubleshooting ACL 9 ACL application failure with an error message 9 Symptom 9 Solution 9 ACL application failure without an error message 9 Symptom 9 Troublesho...

Page 3: ...Solution 24 Related commands 27 Layer 3 forwarding failure 28 Symptom 28 Troubleshooting flowchart 28 Solution 29 Related commands 29 Protocol flapping 29 Symptom 29 Troubleshooting flowchart 30 Solut...

Page 4: ...Status of the LEDs Measures you have taken such as reconfiguration cable swapping and reboot Output from the commands executed during the troubleshooting process To ensure safety wear an ESD wrist str...

Page 5: ...mon log messages from the log buffer to a log file By default the log file is saved in the logfile directory of the flash memory on each member device Sysname logfile save The contents in the log file...

Page 6: ...to a file or displaying the statistics on the screen When you collect operating statistics follow these guidelines Log in to the device through a network port or management port if any instead of the...

Page 7: ...r gz 524288 KB total 107944 KB free To display operating statistics on the monitor terminal enter n at the prompt The output from this command varies by software version Save or display diagnostic inf...

Page 8: ...d switch reboot removable power modules and fixed fan trays To troubleshoot transceiver modules and ports see Troubleshooting ports Unexpected switch reboot Symptom The switch reboots unexpectedly whe...

Page 9: ...e is in Absent state go to step 2 If the power module is in Fault state go to step 3 2 Remove and reinstall the power module to make sure the power module is installed correctly Then execute the displ...

Page 10: ...nd to verify that the power module has changed to Normal state If the power module remains in Absent state go to step b b Remove and install the power module into an empty power module slot Then execu...

Page 11: ...8 Related commands This section lists the commands that you might use for troubleshooting fan trays Command Description display fan Displays fan tray operating status information...

Page 12: ...n To resolve the problem 1 Execute the display qos acl resource command and then check the Remaining field for ACL resources insufficiency If this field displays 0 the ACL hardware resources are exhau...

Page 13: ...qos policy interface VLAN display qos vlan policy Global display qos policy global Control plane display qos policy control plane slot slot number b If the QoS policy does not contain a class behavio...

Page 14: ...correctly reconfigure it If the ACL is configured correctly go to step 3 3 If the problem persists contact H3C Support Related commands This section lists the commands that you might use for troublesh...

Page 15: ...12 Troubleshooting IRF This section provides troubleshooting information for common problems with IRF IRF fabric establishment failure Symptom An IRF fabric cannot be established...

Page 16: ...o Yes Yes No Yes Resolved No Yes Yes No Yes No Yes You cannot add devices to the IRF fabric Yes No Member ID unique Modify IRF port bindings or reconnect physical ports Number of members fewer than th...

Page 17: ...e SFP ports verify that the transceiver modules or cables for IRF connections are labeled with 10Gbps or SFP If you use transceiver modules and fibers for IRF connections make sure the transceiver mod...

Page 18: ...that each IRF port has a minimum of one physical port in up state display irf Displays IRF fabric information including the member ID role priority bridge MAC address and description of each IRF membe...

Page 19: ...tion This section provides troubleshooting information for common problems with Ethernet link aggregation Link aggregation failure Symptom Some member ports fail to be placed in Selected state and lin...

Page 20: ...lure Solution To resolve the problem 1 Verify that all physical connections are correct You can verify the physical connections against your network plan 2 Verify that all member ports are up a Execut...

Page 21: ...ence port 6 Verify that the number of member ports in the aggregation group does not exceed the configured maximum number of Selected ports a Execute the link aggregation selected port maximum command...

Page 22: ...lems A fiber port fails to come up Symptom A fiber port fails to come up Troubleshooting flowchart Figure 5 Troubleshooting link up failure on a fiber port Solution To resolve the problem 1 Verify tha...

Page 23: ...at the transceiver module and cable are operating correctly a Use the display transceiver alarm interface command to display the alarms present on the transceiver module The device displays None if no...

Page 24: ...ort 2 Replace the network cable with a new one to verify that the network cable is in good condition 3 Replace the local port with a new one to verify that the local port is operating correctly 4 Repl...

Page 25: ...c information Displays or saves running status data for multiple feature modules display interface brief Displays brief interface information display transceiver alarm interface Displays alarms presen...

Page 26: ...Layer 2 packet loss failure Incoming error packets No Yes Yes Troubleshoot the problem End No Yes Layer 2 packet loss Packets filtered by ACLs or QoS policies Troubleshoot the problem Port blocked No...

Page 27: ...owing failures might occur Interface hardware failure To test such a failure connect the cable that is connected to the local port to a correctly operating port for example Port A with the same config...

Page 28: ...output shows that Smartrate Ethernet 1 0 1 is associated with chip port xe1 Execute the bcm slot 1 chip 0 show c xe1 command to check the RDBGC and TDBGC fields for Rx and Tx dropped packet statistics...

Page 29: ...nd If the ip source binding command or ip verify source command is configured but the packets match no entry further troubleshoot the problem based on the way the binding entries are created The porta...

Page 30: ...hole MAC address entry execute the undo mac address blackhole mac address vlan vlan id command Rate limit Execute the display qos lr interface command to display the rate limit configuration on the po...

Page 31: ...ation about global QoS policies display qos policy interface Displays information about the QoS policies applied to an interface or all interfaces display qos queue interface Displays traffic statisti...

Page 32: ...arn ARP entries again 3 Verify that route entries are correct a Execute the display ip routing table command to verify that route entries are correct If incorrect route entries exist troubleshoot the...

Page 33: ...debug rxtx softcar slot 1 ID Type RcvPps Rcv_All DisPkt_All Pps Dyn Swi Hash ACLmax 0 ROOT 0 0 0 300 S On SMAC 0 1 ISIS 0 0 0 200 D On SMAC 8 2 ESIS 0 0 0 100 S On SMAC 8 3 CLNP 0 0 0 100 S On SMAC 8...

Page 34: ...witch use the PoE power according to the PoE power supply scheme For information about the power supply compatibility see H3C S5150 EI Switch Series Installation Guide 2 Execute the following commands...

Page 35: ...rect Nonstandard PD detection by the PSE is enabled Sysname display poe pse PSE ID 4 PSE Slot No 1 PSE SubSlot No 0 PSE Model LSW124POED M PSE Power Enabled enabled PSE Power Priority PSE Current Powe...

Page 36: ...PoE interface execute the poe max power command to configure the maximum power with higher wattage supply 3 If the problem persists contact H3C Support Related commands This section lists the command...

Reviews: