Removable power module failure
The S5130S-28F-EI and S5130S-52F-EI switches use removable power modules. You can
determine the power module operating status by examining the power module LEDs PWR1 and
PWR2 on the switch front panel. For descriptions about the PWR1 and PWR2 LEDs, see "
."
Symptom
A power module LED on the front panel of the switch is not steady green.
Solution
To resolve the issue:
1.
Verify that the AC or DC power cord is correctly connected to the switch.
2.
Verify that the power module model is as required.
3.
Verify that the power module is installed correctly in the switch.
4.
Verify that the switch is operating in the acceptable temperature range.
5.
If the power module needs to be replaced, see "
Installing and removing power modules
" to
replace the power module.
6.
If the issue persists, contact H3C Support.
Fan tray failure
Symptom
The system status LED on the switch indicates a fan tray failure.
Solution
When a fan tray issue occurs, contact H3C Support.
Configuration terminal issues
No display on the configuration terminal
Symptom
The configuration terminal does not have display when the switch is powered on.
Solution
To resolve the issue:
1.
Verify that the power system is operating correctly.
2.
Verify that the switch is operating correctly.
3.
Verify that the console cable has been connected correctly.
4.
Verify that the following settings are configured for the terminal:
Baud rate
—9600.