10
The dimensions of the angle iron must be at least 50 × 50 × 5 mm (1.97 × 1.97 × 0.20 in). The steel
tube must be zinc-coated and its wall thickness must be at least 3.5 mm (0.14 in).
Weld the yellow-green grounding cable to the angel iron or steel tube and treat the joint for corrosion
protection.
Figure 13 Grounding the switch by burying the grounding conductor into the earth ground
(1) Grounding screw
(2) Grounding cable
(3) Earth
(4) Joint
(5) Grounding conductor
(6) Chassis rear panel
Installing and removing a power module
(S5130-28F-EI switch)
CAUTION:
Provide a circuit breaker for each power module and make sure the circuit breaker is off before
installation.
The S5130-28F-EI switch provides two power module slots and comes with power module slot 1
empty and a filler panel in power module slot 2. You can install one power module, or two power
modules for redundancy. For information about power modules available for the S5130-28F-EI
switch, see "
When two power modules are installed, you can hot-swap a power module. To avoid device damage
and bodily injury, follow the procedures in
to install and replace a power
module.
Figure 14 Installation procedure
Figure 15 Removal procedure
The installation and removal procedures are the same for the PSR150-A1, PSR150-A, and
PSR150-D1 power modules. This guide uses the
PSR150-A power module as an example.