Installation Manual
H3C S3610 Series Ethernet Switches
Chapter 3 Installing the Switch
3-5
5) Fix the other end of front mounting ears to the front brackets of the cabinet with M6
screws and captive nuts and ensure that the front mounting ears and guide rails
have fixed the switch in the cabinet securely, as shown in Figure 3-7.
Figure 3-7
Effect diagram of front mounting ear and guide rail installation
3.1.2 Mounting a Switch on a Workbench
In many cases, 19-inch standard cabinets are not available. Therefore, switches are
often installed on clean workbenches. To install your switch on a workbench, you simply
need to:
z
Make sure that the workbench is flat and sturdy and well earthed.
z
Leave a clearance of 10 cm (3.94 in.) around the device for heat dissipation.
z
Do not lay heavy objects on the switch.
3.2 Connecting the Power Cord and the Ground Wire
3.2.1 Connecting the AC-Input Power Cord
I. AC-input power socket (recommended)
You are recommended to use a monophase three-line power socket with a ground
contact or a general purpose PC power socket, making sure that the power point is well
connected to building ground. Normally, the ground point of the power source in a
building was buried in the ground during the construction and wiring. Still, you must
make sure of that.