Operation Manual – NQA
H3C S3610&S5510 Series Ethernet Switches
Chapter 1 NQA Configuration
1-27
Failures due to Internal Error: 0
Failures due to Other Errors: 0
1.3 Configuring Optional Parameters for NQA Tests
Unless otherwise specified, the following parameters are applicable to all test types and
they can be configured according to the actual conditions. Optional parameters
common to NQA are valid for all NQA tests, while those common to an NQA test group
are valid only for tests in this test group. This section covers these topics:
z
Configuring Optional Parameters Common to NQA
z
Configuring Optional Parameters Common to an NQA Test Group
z
1.3.1 Configuring Optional Parameters Common to NQA
Follow these steps to configure optional parameters common to NQA:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the maximum
number of tests that the
NQA client can
simultaneously perform
nqa-agent max-requests
number
Optional
5 by default
1.3.2 Configuring Optional Parameters Common to an NQA Test Group
Follow these steps to configure the optional parameters common to an NQA test group:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter NQA test group
view
nqa
admin-name
operation-tag
—
Configure a descriptive
string for a test group
description
text
Optional
No descriptive string by
default.
Configure the interval of
performing a cyclic test
frequency
interval
Optional
No cyclic test is performed
by default.
This command is invalid for