Operation Manual – MSTP
H3C S3100-52P Ethernet Switch
Chapter 1 MSTP Configuration
1-42
To do...
Use the command...
Remarks
Enter system view
system-view
—
Perform the mCheck
operation
stp
[
interface
interface-list
]
mcheck
Required
II. Perform the mCheck operation in Ethernet port view
Follow these steps to perform the mCheck operation in Ethernet port view:
To do...
Use the command...
Remarks
Enter system view
system-view
—
Enter Ethernet port view
interface
interface-type
interface-number
—
Perform the mCheck
operation
stp mcheck
Required
1.5.3 Configuration Example
# Perform the mCheck operation on Ethernet 1/0/1.
1) Perform this configuration in system view
<Sysname> system-view
[Sysname] stp interface Ethernet 1/0/1 mcheck
2) Perform this configuration in Ethernet port view
<Sysname> system-view
[Sysname] interface Ethernet 1/0/1
[Sysname-Ethernet1/0/1] stp mcheck
1.6 Configuring Guard Functions
1.6.1 Introduction
The following guard functions are available on an MSTP-enabled switch: BPDU guard,
root guard, loop guard, TC-BPDU attack guard, and BPDU drop.
I. BPDU guard
Normally, the access ports of the devices operating on the access layer are directly
connected to terminals (such as PCs) or file servers. These ports are usually
configured as edge ports to achieve rapid transition. But they resume non-edge ports
automatically upon receiving configuration BPDUs, which causes spanning tree
recalculation and network topology jitter.