2-4
Fabric module slot filler panels
The device comes with empty fabric module slots. For good ventilation, purchase and install filler
panels in the empty fabric module slots.
Table 2-5 Fabric module slot filler panels
Item
Quantity per chassis
S12516R fabric module slot filler panel
0 to 4
S12508R fabric module slot filler panel
0 to 4
S12504R fabric module slot filler panel
0 to 4
Slide rails
No slide rails are provided with the device. Purchase slide rails for the device as needed.
Table 2-6 Slide rails available for the device
Device model
Chassis weight
(fully configured)
Applicable slide rails
Slide rail model
Adjustment range
Occupied
space
S12516R
400 kg (881.83 lb)
LSXM1BSR
630 mm to 900 mm
(24.80 in to 35.43 in)
1 RU
S12508R
220 kg (485.01 lb)
LSXM1BSR
630 mm to 900 mm
(24.80 in to 35.43 in)
1 RU
LSTM2KSGD0
500 mm to 800 mm
(19.69 in to 31.50 in)
2 RU
S12504R
120 kg (264.55 lb)
LSVM1BSR10
630 mm to 850 mm
(24.80 in to 33.46 in)
N/A
Power modules
CAUTION:
You must install power modules of the same model for the device.
The device supports N+N (dual power input lines) or N+1 (single power input line) power module
redundancy. Determine the number of power modules based on the power supply mode and system
power consumption. Make sure the maximum total output power of the device power modules is
greater than the system power consumption. Reserve a 20% power surplus as a best practice.