Configuration files
#
interface M-GigabitEthernet0/0/0
port link-mode bridge
ip address 192.168.100.66 255.255.255.0
#
local-user abc class manage
password hash
$h$6$YMVbbwFL/vCuTbYCehNZtZo5RCXiadpYbXYWa2omt5TUtEh3UPCg3fZjxYCp5WzbuE2GoowV
i2YA/BK+mnSZJZqi5jRDuCg==
service-type ftp
authorization-attribute user-role network-admin
#
ftp server enable
#
Upgrading software from the Boot menu
Example: Using the device as a TFTP client to upgrade
software
Network requirements
As shown in
, upgrade software from the BootWare menu. Download software images from a
TFTP server.
Figure 6
Network diagram
Software version used
This configuration example was created and verified on S12500-CMW710-R7328P02.
Configuration restrictions and guidelines
When you upgrade software, follow these restrictions and guidelines:
•
Make sure the device has sufficient storage space for the upgrade file. If the device does not have
sufficient storage space, delete unused files by using the
delete /unreserved
file
-
url
command.
•
Connect the device to the TFTP server through the management Ethernet interface
M-GigabitEthernet 0/0/0.
Configuration procedures
1.
Configure the host: