46
(1) 10/100/1000BASE-T ports
(2) RUN/ALM LED
(3) 10GBASE-R-SFP+ fiber ports
(4) 10GBASE-R-SFP+ fiber port LEDs
(5) 10/100/1000BASE-T ports LEDs
Table 47 LED description
LED
Status
Description
SFP+ port LED
Flashing
The SFP+ port is sending or receiving data.
On
A link is present on the SFP+ port.
Off
No link is present on the SFP+ port.
RJ-45 Ethernet port LED
Flashing
The port is sending or receiving data.
On
A link is present on the port.
Off
No link is present on the port.
RUN/ALM LED
Flashing green (once per
two seconds)
The interface module is operating correctly.
Flashing green (four
times per second)
The interface module is loading software.
Steady green
The interface module is starting up.
Steady red
The interface module is faulty, or a high severity
alarm has occurred on the interface module.
Flashing red (once per
four seconds)
The temperature of the interface module has
exceeded the upper warning threshold or fell below
the lower warning threshold.
Off
The interface module is faulty or not present.
NOTE:
You can identify the rate of an SFP+ port by observing the color of its LED. When the LED is green,
the SFP+ port is operating at 10 Gbps. When the LED is yellow, the SFP+ port is operating at 1000
Mbps.
LSEM1GV48TSSD0
View
Figure 45 LSEM1GV48TSSD0 interface module view