6
Note:
The design of this product complies with
environmental protection requirements. Be sure
to observe the relevant local laws and regulations
when storing, using or disposing of this product.
The RPS1000-A3 supports a variety of protection
features, as shown in Table 3 on page 6.
Table 3
Protection features of the RPS1000-A3
Item
Description
Input
over-voltage
protection
When the input voltage exceeds 312 ±
5 VAC, the unit comes into an
over-voltage protection shutdown and
generates an alarm.
When the input voltage comes down to
310 ± 5 VAC, the unit automatically
recovers and clears the alarm.
Input
under-voltage
protection
When the input voltage comes down to
85 ± 5 VAC, the unit comes into an
under-voltage protection shutdown and
generates an alarm.
When the input voltage rises to 89 ± 5
VAC, the unit automatically recovers
and clears the alarm.