background image

 

H3C PSR650C-12A 

& PSR650C-12D Power Modules 

User Manual

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
New H3C Technologies Co., Ltd.

 

 

http://www.h3c.com 
 
 
Document version: 6PW101-20220922 

 

Summary of Contents for PSR650C-12A

Page 1: ...H3C PSR650C 12A PSR650C 12D Power Modules User Manual New H3C Technologies Co Ltd http www h3c com Document version 6PW101 20220922 ...

Page 2: ...r respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accurate but they are presented without warranty of any kind express or implied H3C shall not be liable for technical or editorial errors or omissions contained herein Environmental protection This prod...

Page 3: ... Technical specifications 2 LEDs 3 Installing and removing the power module 5 Safety precautions 5 Installing the power module 5 Removing the power module 7 Connecting the power cord 9 Connecting the AC power cord 9 Connecting the DC power cord 11 ...

Page 4: ... of 650 W The power modules support 1 1 redundancy and load sharing and are removable They also provide output overcurrent output overvoltage output short circuit and overtemperature protections Front panel Figure 1 PSR650C 12A front panel 1 Captive screw 2 Power switch 3 Power input LED 4 Power output LED 5 Fan status LED 6 Handle 7 Power receptacle 1 2 4 5 3 7 6 ...

Page 5: ...ut LED 5 Fan status LED 6 DC input positive terminal 7 DC input negative terminal 8 Grounding point 9 Handle Technical specifications Table 1 Technical specifications Item PSR650C 12A PSR650C 12D Rated input voltage 100 to 240 VAC 50 or 60 Hz 48 to 60 VDC Output voltage 12 V 12 V 4 5 3 6 8 7 9 1 2 ...

Page 6: ...F Operating humidity 5 RH to 95 RH 5 RH to 95 RH LEDs The PSR650C 12A PSR650C 12D power module provides three red green status LEDs Table 2 LED description LED Status Description INPUT Green The power is being input correctly Red A power input problem has occurred because the input voltage is out of the rated voltage range Off No power is being input because one of the following conditions exists ...

Page 7: ... power module is switched off Off No power is being output because one of the following conditions exists The power module is faulty The power cord is disconnected The power source is unavailable FAN Green The fans are operating correctly Red The fans are operating incorrectly because one of the following conditions exists A fan failure has occurred The power module is switched off Off The fans st...

Page 8: ... you install the power module make sure the output voltage of the power module is as required by the device When you move the power module support its bottom instead of only holding the power handle To avoid device damage do not install power modules of different models on the same device Do not touch any bare cables or terminals of the power module Do not place the power module in a wet area and ...

Page 9: ...the filler panel if any from the target slot Keep the removed filler panel for future use 3 Unpack the power module Make sure the power module model is as required 4 Correctly orient the power module 5 Holding the handle of the power module with one hand and supporting the bottom of the power module with the other slide the power module along the guide rails into the slot until the Remove the fill...

Page 10: ...istance while inserting the power module or fastening a captive screw pull out the power module reorient it and then insert it again Figure 4 Installing the power module Removing the power module To avoid device damage and bodily injury follow the procedure in Figure 5 to remove the power module 1 2 2 ...

Page 11: ...ly grounded 4 Switch off the power module 5 Remove the power cord connected to the power module 6 Use a Phillips screwdriver to loosen the captive screws on the power module 7 Holding the power module handle with one hand and supporting the bottom of the power module with the other gently pull the power module out 8 Put the removed power module on the antistatic mat Turn off the circuit breaker Re...

Page 12: ...r panel over the empty power module slot Figure 6 Removing the power module Connecting the power cord Connecting the AC power cord WARNING Make sure each power module has a separate circuit breaker Turn off the circuit breaker before connecting the power cord 1 2 1 ...

Page 13: ...ct the power cord to the power receptacle of the power module Make sure the power cord is securely inserted into the power receptacle 3 Use a cable tie to secure the power cord to the handle of the power module 4 Connect the other end of the power cord to the AC power source Figure 7 Connecting the AC power cord ...

Page 14: ... wiring terminal with a Phillips screwdriver 3 Connect one ends of the wires to the power input terminals on the power module with the negative wire or L to the negative terminal and the positive wire or M N to the positive terminal 4 Put the protection cover on the wiring terminals 5 Connect the other ends of the wires to the DC power source wiring terminals with the negative wire or L to the neg...

Page 15: ...ord NOTE The power cord color code scheme in Figure 8 is for illustration only The cord delivered for your country or region might use a different color scheme When you connect a power cord always identify the polarity symbol on its wires ...

Reviews: