285
Usage guidelines
Use this command to clear history statistics if you want to collect traffic statistics for a specific period.
•
If you do not specify an interface type, the command clears statistics on all interfaces.
•
If you specify the
eth-channel
keyword without specifying the channel ID, the command clears
statistics on all Eth-channel interfaces.
•
If you specify both the
eth-channel
keyword and the channel ID, the command clears statistics
on the specified Eth-channel interface.
Examples
# Clear the statistics on Eth-channel 2/4/0:0.
<Sysname> reset counters interface eth-channel 2/4/0:0
shutdown
Use
shutdown
to shut down an Eth-channel interface.
Use
undo shutdown
to bring up an Eth-channel interface.
Syntax
shutdown
undo shutdown
Default
An Eth-channel interface is up.
Views
Eth-channel interface view
Predefined user roles
network-admin
Examples
# Shut down Eth-channel 2/4/0:0.
<Sysname> system-view
[Sysname] interface eth-channel 2/4/0:0
[Sysname-Eth-channel2/4/0:0] shutdown
Summary of Contents for MSR810
Page 148: ...136 Related commands timer hold...
Page 331: ...319 Related commands timer hold...