H3C LSXM1SEERBXD2 DC SeerEngine Module 

1  Identifier 

The module identifier LSXM1SEERBXD2 is at the right of the front panel. 

2  About the module 

The  LSXM1SEERBXD2  is a  data center  (DC)  SeerEngine  module preinstalled with application 
driven data center (ADDC)  solution components such as SeerNetwork architecture (SNA)  center 
and SeerEngine. It can be used to build a stateless network for small and medium-sized data centers. 
It enables pooling of all computing, network, and security resources and provides complete virtual 
data center (vDC) capabilities, eliminating the need to install physical servers. 

Figure 1 LSXM1SEERBXD2 front panel 

 

(1) SFP+ fiber ports (3 in total) 

(2) Data drive ports (SSD0 and SSD1) 

(3) HDM shared network port 

(4) USB 3.0 port 

(5) Console port 

(6) HDM dedicated network port 

(7) UID button/LED 

(8) Power on/standby button and system power LED 

(9) Health LED 

(10) HDM dedicated network port LED (ACT) 

(11) HDM dedicated network port LED (LINK) 

(12) HDM shared network port LED 

(13) SFP+ fiber port state LED 

(14) SUV port (using an SUV connector) 

(15) SFP+ fiber port LEDs (ACT) 

(16) SFP+ fiber port LEDs (LINK) 

 

3  Specifications 

Table 1 Module specifications 

Item 

Specifications 

Drive 

 

2 × 960GB system solid-state drives (SSD) 

 

2 × 1TB data SSDs 

Memory 

8 memory slots 

Standard configuration: 256 GB (8 × 32 GB memory bars) 

Dimensions (H × W × D) 

50 × 433 × 520 mm (1.97 × 17.05 × 20.47 in) 

Power consumption 

140 to 285 W 

SSD hot swapping 

Not supported 

4

2

1

16

7

8

14

15

15 16

1

9

5

6

3

10

11

12

13

Summary of Contents for LSXM1SEERBXD2

Page 1: ...ure 1 LSXM1SEERBXD2 front panel 1 SFP fiber ports 3 in total 2 Data drive ports SSD0 and SSD1 3 HDM shared network port 4 USB 3 0 port 5 Console port 6 HDM dedicated network port 7 UID button LED 8 Power on standby button and system power LED 9 Health LED 10 HDM dedicated network port LED ACT 11 HDM dedicated network port LED LINK 12 HDM shared network port LED 13 SFP fiber port state LED 14 SUV p...

Page 2: ...pecification Connector RJ 45 Standard 802 3 802 3u and 802 3ab Auto MDI MDIX Supported Cable Category 5 or above twisted pair cable Transmission distance 100 m 328 08 ft Rate and duplex mode 10 100 1000 Mbps full duplex mode NOTE This module can be used only with Type T fabric modules such as LSXM1SFT08F2 and Type T supervisor engine units such as LSXM2SUPT2 To verify the compatibility of the modu...

Page 3: ...r 8 seconds Off The UID LED is not activated HDM dedicated network port LED LINK and ACT LINK ACT Steady on Flashing A link is present on the port and the port is receiving or transmitting data Steady on Off A link is present on the port Off Off No link is present on the port SFP fiber port HDM shared network port state LED Steady on A link is present on the port Flashing The port is receiving or ...

Page 4: ...e removing the module press the power on standby button on the module for a minimum of 2 seconds until the system power LED is off To remove the module 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Use a Phillips screwdriver to loosen the captive screws on the module 3 Simultaneously open the ejector levers of the module to disengage the module conne...

Page 5: ...BOM 3123A1WR v 6 Software upgrade For information about upgrading the software see the release notes for the module Copyright 2020 2021 New H3C Technologies Co Ltd The information in this document is subject to change without notice ...

Reviews: