background image

 

3-2 

 

The insertion and reverse insertion procedures are the same. This manual uses reverse insertion of an 

OAP card to an S5800-60C-PWR switch as an example. 

 

Figure 3-2 

Insert an OAP card 

 

 

Figure 3-3 

Reversely insert an OAP card 

 

 

Step4 

Push the OAP card slowly along the guide rails (see (3) in  Figure 3-4) and then push the ejector levers 

inward to lock the OAP card in position (see (4) in  Figure 3-4).  

Figure 3-4 

Install the OAP card to the switch 

(1)

(2)

(3)

(4)

 

(1) OAP card 

(2) Rear panel of the switch 

(3) Insertion direction of the OAP card 

(4) Locking direction of the ejector levers 

 

Summary of Contents for LSWM1FW10

Page 1: ...H3C OAP Cards User Manual New H3C Technologies Co Ltd http www h3c com Manual Version 6PW102 20180112...

Page 2: ...ne SecPath SecCenter SecBlade Comware ITCMM and HUASAN are trademarks of New H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective owne...

Page 3: ...cause data loss or damage to equipment Means a complementary description Obtaining Documentation and Technical Support To obtain up to date documentation and technical support go to http www h3c com a...

Page 4: ...nce 2 1 Front Panel 2 1 Appearance 2 1 Description of the LEDs 2 1 Management Ethernet Port 2 2 Hardware Specifications 2 3 3 Installing an OAP Card 3 1 Installing and Removing an OAP Card 3 1 Connect...

Page 5: ...tack defense and P2P flow control thus effectively ensuring network security supports multiple VPN services such as IPsec VPN thus allowing you to build various VPNs supports multiple routing protocol...

Page 6: ...ll card Appearance Figure 2 1 OAP card appearance 1 Ejector lever 2 Fastening screw captive screw 3 Front panel of the OAP card Front Panel Appearance Figure 2 2 Front panel of an OAP card 1 CF card i...

Page 7: ...een Steady green The CF card is normal and no read write operation is performed Blinking green The CF card is normal and a read write operation is performed Off No CF card is in the slot Management Et...

Page 8: ...AP card hardware specifications Item Specification Remarks CPU MIPS eight cores 1 GHz Memory 2 GB Avoid replacing the memory by yourself to prevent damage to the OAP card Number of CF card interfaces...

Page 9: ...rap ensure a good skin contact and make sure that the ESD preventive wrist strap is properly grounded Step2 Loosen the captive screws on the blank panel counterclockwise with a Phillips screwdriver as...

Page 10: ...ard Figure 3 3 Reversely insert an OAP card Step4 Push the OAP card slowly along the guide rails see 3 in Figure 3 4 and then push the ejector levers inward to lock the OAP card in position see 4 in F...

Page 11: ...ly grounded Step2 Loosen the captive screws on the OAP card counterclockwise with the Philips screwdriver until all spring pressure is released Step3 Hold each ejector lever with a hand and pull the e...

Page 12: ...OAP card to the Ethernet port of a PC or router use a crossover cable z To connect the management Ethernet port of an OAP card to the Ethernet port of a hub or switch use a straight through cable Ste...