5-11
Figure 5-6
Download the file using Xmodem
Upon successful download, the system displays the following information:
Download successfully!
354944 bytes downloaded!
Updating Basic BootWare? [Y/N]Y
Updating Basic BootWare...............Done!
Updating Extend BootWare? [Y/N]Y
Updating Extend BootWare..............Done!
9) Change the baud rate on the console terminal from 115,200 bps back to 9,600 bps, and reboot the
LSQM1WCMB0 access controller module.
z
The actual file name, size and path may differ from what are shown in the figure above. Before
upgrading the software, check the current BootWare version and application program version to
make sure that the correct file is used for the upgrade.
z
After you download files with a changed baud rate, timely change the baud rate back to 9,600 bps
in HyperTerminal to ensure the normal display on the console screen when the system boots or
reboots.
Upgrading the BootWare Through the Management Ethernet Interface
Follow these steps to upgrade the BootWare through the management Ethernet interface:
1) Enter the BootWare main menu (refer to section “BootWare Main Menu” on page 5-3), select
7
to
enter the BootWare operation submenu. For details about this menu, refer to section “BootWare
operation submenu” on page 5-6.